7.SERIAL INTERFACE
7.1Specifications
(1) | Synchronous system | : Asynchronous |
(2) | Baud rate | : 150, 300, 600, 1,200, 2,400, 4,800, 9,600, 19,200 bps |
|
| (Selected by the user) |
(3) |
| |
| Start bit | : 1 bit |
| Data bits | : 8 bits or 7 bits (Selected by the user) |
| Parity bit | : Odd, even, or no parity (Selected by the user) |
| Stop bit | : 1 bit or more |
(4)Signal polarity
| • Mark | = | Logic "1" | ||
| • Space | = | Logic "0" (+3 ∼ +12 V) | ||
(5) | Received data (RD signal) |
|
| ||
| • Mark | = | 1 |
|
|
| • Space | = | 0 |
|
|
(6) | Reception control (DTR signal) |
| |||
| • Mark | : | Data not transferable | ||
| • Space | : | Data transferable | ||
(7) | Transmission control (TD signal) |
| |||
| • DC1 code(11H) | : | Data receivable | ||
| • DC3 code(13H) | : | Data not receivable |
7.2Connector's Pin Configuration
No. | Signal Name | Input/Output | Function |
1 | FG | | Frame Ground |
7 | GND | | Signal Ground |
|
|
|
|
3 | RD | Input | Received Data |
20 | DTR | Output | Printer BUSY Signal |
2 | TD | Output | Transmitted Data |
6 | DSR | Input | Data Set Ready |
|
|
|
|
Notes: 1. | The | |
2. | The received data should be always maintained in the Mark status when no data is being | |
| transferred. |
|
| Applicable connectors | |
| Printer side | : |
| Cable side | : |
29 | CITIZEN |