Started Getting

Make the Optimal Speaker Settings, and Correct the Room Acoustics (Audyssey™ Auto Setup)

Subwoofer Level Error Message and How to Adjust

The optimal level of the subwoofer channel is 75 dB. During subwoofer level measurement (d:Perform Audyssey Auto Setup, “ STEP2 : Speaker Detection” (vpage 35), 1 - q), an error message is displayed when the subwoofer level is outside the 72 ~ 78 dB range. When using a subwoofer with built-in amplifier (active type), adjust the subwoofer volume so that the subwoofer level is within the 72 ~ 78 dB range.

Check the Measuring Results and Equalizer Type after Audyssey Auto Setup (Parameter Check)

Playback Settings Connections

1Select “SW Level Matching” and then press ENTER.

3Adjust the volume control on your subwoofer so that the measured level is within the 72 ~ 78 dB

range. Blue

This is displayed after Audyssey Auto Setup is completed.

1Press i to select “Parameter Check”, and then press

ENTER or p.

Specifications Troubleshooting Information Control Remote zone-Multi

2Select “SW Test Start” and then press

ENTER.

Subwoofer level measurement begins. During measuring, a “Testing …” message is displayed.

The measured level appears on the level indicator after about 3 ~ 5 seconds.

Red

b If the measured level is outside the 72 ~ 78 dB range, the level indicator is red.

b When measuring stops, press ENTER.

b If the measured level is within the 72 ~ 78 dB range, the level indicator is blue.

4When the measured level is within the 72 ~ 78 dB range, press ENTER.

5Select “Next” and then press ENTER.

Proceed to “d:Perform Audyssey Auto Setup, STEP2 : Speaker Detection” (vpage 35), 1 - w.

2Press ui to select the item you want to check, and then press ENTER or p.

Speaker Config. Check

 

Distance Check

 

Channel Level Check

 

 

 

Crossover Freq. Check

 

EQ Check

 

 

 

 

 

 

3 Press ui to select the channel you want to check. The measurement result of each speaker is displayed.

bWhen you selected “EQ Check” in step 2, press uito select the Correction curve you want to check (“Audyssey” or “Audyssey Flat”).

b When you want to check another item, press RETURN.

Pressing RETURN returns you to step 2; from there, proceed to steps 2 and 3.

If you set “Restore” to “Yes”, you can return to Audyssey Auto Setup measurement result (value calculated at the start by MultEQ XT) even when you have changed each setting manually.

38

Main remote control unit

:Displaying the menu

:Moves the cursor

:Confirm the setting

:Return to previous menu

 

operation buttons

Cancel the menu

(Up/Down/Left/Right)