OCX 8800

Figure 7-15. Band Heater Height

COe Sensor

 

0.37 in.

 

 

(9,4 mm)

 

 

Band Heater

Insulator

37390058

Install COe Sensor Assembly

1.Apply pipe thread sealant (Loctite #567) to the exposed pipe threads of eductor elbow (12, Figure 7-13). Do not apply sealant to the first turn of the pipe threads.

2.Screw sensor holder (11) onto eductor elbow (12).

3.With wrenches on eductor elbow (12) and on flats of sensor holder (11), tighten sensor holder. Do not allow eductor elbow to turn.

4.Tighten sensor holder (11) to align outside flat with matchmark on sensor housing flange, as shown in Figure 7-16.

The heater insulator prevents current leakage between the band heater and the sensor holder. Failure to properly install the insulator may cause the device to trip a ground fault interrupt circuit.

5.Wrap heater insulator (9) around sensor holder (11). Make sure the insulator joint lines up with the band gap of the COe band heater (10).

6.Slide COe band heater (10, Figure 7-13) up onto sensor holder (11). Do not tighten the band heater at this time. Heater must rotate freely around sensor holder.

7.Check for proper height of COe heater thermocouple (Figure 7-12). Thread bayonet connector up or down to adjust height.

8.Install and fasten thermocouple (8, Figure 7-13).

9.Position band heater as shown in Figure 7-15 and Figure 7-16 and tighten band heater clamp screw. The heater insulator (9) end joint must line up with the band gap of the COe band heater (10).