Model 54eA
Amperometric HART
®
Analyzer/Controller
Instruction Manual
51-54eA/rev.J
May 2006
Contents
Main
ESSENTIAL INSTRUCTIONS
READ THIS PAGE BEFORE PROCEEDING!
WARNING
ELECTRICAL SHOCK HAZARD
WARNING
Page
MODEL 54eA ANALYZER/CONTROLLER
TABLE OF CONTENTS Section Title Page
TABLE OF CONTENTS (CONTINUED) Section Title Page
LIST OF FIGURES
SECTION 1.0 SPECIFICATIONS
1.1 FEATURES AND APPLICATIONS
1.2 SPECIFICATIONS - GENERAL
SPECIFICATIONS OXYGEN
RECOMMENDED SENSORS OXYGEN:
SPECIFICATIONS FREE CHLORINE
RECOMMENDED SENSOR FREE CHLORINE:
SPECIFICATIONS pH
1.3 ORDERING INFORMATION
SECTION 2.0 INSTALLATION
2.1 UNPACKING AND INSPECTION
2.2 INSTALLATION
40005402 E
FIGURE 2-4. Panel Mounting
40005401 D
2.2.4 Panel mounting
FIGURE 2-5. Panel Mounting Dimensions
7
SECTION 3.0 WIRING
3.1 GENERAL
3.2 POWER, ALARM, AND OUTPUT WIRING
NOTE
Page
3.3 SENSOR WIRING
40054e03 A
40499A24 A
40499A23 A
4054eA01 B
MODEL 54eA SECTION 3.0 WIRING
FIGURE 3-6. 499ACL-01 sensor with standard cable and 399-14 pH sensor having internal preamplifier.
FIGURE 3-7. 499ACL-01 sensor with standard cable and 399-09-62 pH without internal preamplifier.
4054eA05 A
4054eA03 A
4054eA02 B
4054eA06 A
4054eA04 A
4054eA07 A
SECTION 4.0 DISPLAY AND OPERATION
4.1 GENERAL DESCRIPTION
4.2 DISPLAY
4.3 KEY FUNCTIONS AND CONTROLS
1.00
26.2C. 12.00 mA pH: 8.00 I: 340 nA
17
SECTION 5.0 SOFTWARE CONFIGURATION
Page
Page
Page
FIGURE 5-1. Menu Tree for the 54eA Controller
21
22
MODEL 54eA SECTION 5.0 SOFTWARE CONFIGURATION
Continued on page 23
Program
Calibrate (see page 21) Diagnostic Variable (see page 21)
FIGURE 5-1. Menu Tree for the 54eA Controller (continued)
23
Page
Page
Page
Page
Page
Page
Page
Page
Output 2 control Output 2 setup Hold feature setup
5.6 CHANGING OUTPUT PARAMETERS (continued)
Page
Page
5.7 CHANGING ALARM PARAMETERS (continued)
Setpoint : 1.000 ppm Proportional: 100.0% Integral: 0 sec
Alarm 1 control Alarm 1 setup Alarm 2 control
Feed limit : Disable Timeout: 3600 sec
1.000 ppm
26.2C 12.0mA Feed limit alarm 1
5.7 CHANGING ALARM PARAMETERS (continued)
Alarm : Fault
Page
Page
5.8 CONFIGURING THE pH MEASUREMENT (continued)
Diagnostics : Off Glass imp hi: 1000 M Glass imp lo: 20 M
Autocal : Standard Stabilize pH: 0.01 pH Stabilize time: 10 sec
pH diagnostics pH calibration Temperature coeff
5.8 CONFIGURING THE pH MEASUREMENT (continued)
Temp coeff : 0.000 Operate iso: 7.00 pH Sensor iso: 7.00 pH
pH diagnostics pH calibration Temperature coeff
Page
Page
Page
Page
5.13 SECURITY
Lock all : 0 Lock program: 0 Lock config: 0
Noise rejection Main sensor cal Security
5.14 CONTROLLER MODE PRIORITY
TABLE 5-2. Controller Mode Priority Chart
SECTION 6.0 CALIBRATION - TEMPERATURE
6.1 INTRODUCTION
6.2 TEMPERATURE CALIBRATION
25.1 C
Adjust temp :+ 025.1 C
25.1 C
Adjust temp : 25.1 C
SECTION 7.0 CALIBRATION - DISSOLVED OXYGEN
7.1 INTRODUCTION
7.2 ZEROING THE SENSOR
8.20
Page
7.4 CALIBRATING THE SENSOR AGAINST A STANDARD INSTRUMENT
Calibrate in air Calibrate in process Barometric pressure
8.32
Calibrate : 8.32 ppm
763
SECTION 8.0 CALIBRATION - FREE CHLORINE (499ACL-01)
8.1 INTRODUCTION
8.2 ZEROING THE SENSOR
8.3 FULL SCALE CALIBRATION
1.100
8.4 DUAL SLOPE CALIBRATION
Dual range cal
Calibrate low point
Low point : 2.000 ppm
Calibrate high point
High point : 6.000 ppm
SECTION 9.0 CALIBRATION - FREE CHLORINE (498CL-01)
9.1 INTRODUCTION
1.
9.2 ZEROING THE SENSOR
9.3 FULL SCALE CALIBRATION
9.4 DUAL SLOPE CALIBRATION
Dual range cal
Calibrate low point
Low point : 2.000 ppm
Calibrate high point
High point : 6.000 ppm
Page
Page
SECTION 11.0 CALIBRATION - MONOCHLORAMINE
11.1 INTRODUCTION
11.2 ZEROING THE SENSOR
11.3 FULL SCALE CALIBRATION
SECTION 12.0 CALIBRATION - OZONE
12.1 INTRODUCTION
12.2 ZEROING THE SENSOR
12.3 FULL SCALE CALIBRATION
SECTION 13.0 CALIBRATION - pH
13.1 INTRODUCTION
4.02
13.2 AUTOMATIC TWO-POINT CALIBRATION
Buf1done: 4.00 @25C
4.02
Autocal buffer 1
Buffer calibration
10.02
Buf2 done: 10.01 @25C
10.02
Autocal buffer 2
13.3 MANUAL TWO-POINT CALIBRATION
2-pt calibration
4.01
Pt. 1 : 04.00pH 25C
4.01
Calibrate point 1
4.00
Pt. 1 : 4.00pH 25.0C
10.01
Pt. 2 : 10.01pH 25.0C
10.01
7.00
Standardize : 7.00 pH
13.5 pH SLOPE ADJUSTMENT
Buffer calibration
pH slope: 60.00 mV/pH
Page
SECTION 15.0 PID AND TPC CONTROL
15.1 PID CONTROL (CODE -20)
Page
Page
Page
15.2 TIME PROPORTIONAL CONTROL (TPC) MODE (Code -20)
SECTION 16.0 TROUBLESHOOTING
16.1 OVERVIEW
16.2 TROUBLESHOOTING WHEN A FAULT MESSAGE IS SHOWING
Page
16.3 TROUBLESHOOTING WHEN NO FAULT MESSAGE IS SHOWING - TEMPERATURE
16.4 TROUBLESHOOTING WHEN NO FAULT MESSAGE IS SHOWING - OXYGEN
Page
Page
16.5 TROUBLESHOOTING WHEN NO FAULT MESSAGE IS SHOWING - FREE CHLORINE
Page
16.6 TROUBLESHOOTING WHEN NO FAULT MESSAGE IS SHOWING - TOTAL CHLORINE
16.7 TROUBLESHOOTING WHEN NO ERROR MESSAGE IS SHOWING MONOCHLORAMINE
Page
Page
16.8 TROUBLESHOOTING WHEN NO FAULT MESSAGE IS SHOWING - OZONE
Page
16.9 TROUBLESHOOTING WHEN NO FAULT MESSAGE IS SHOWING - pH
Page
Page
16.10 TROUBLESHOOTING NOT RELATED TO MEASUREMENT PROBLEMS
16.11 SIMULATING INPUTS - DISSOLVED OXYGEN
16.12 SIMULATING INPUTS - OTHER AMPEROMETRIC MEASUREMENTS
16.13 SIMULATING INPUTS - pH
16.14 SIMULATING TEMPERATURE
16.15 MEASURING REFERENCE VOLTAGE
SECTION 17.0 MAINTENANCE
SECTION 18.0 RETURN OF MATERIAL