MSG_ID: 1310 Warning: Diagnostic Error

VERBOSE_MASK: LOG_SFS (0x00002000)

DESCRIPTION: This indicates that a diagnostic request did not complete because of some issue.

SEVERITY LEVEL: Warning

MESSAGE: Diagnostic error

ACTION: No action needed. If problems persist, report these errors to Technical Support.

MSG_ID: 1311 Debug: ECHO Diagnostic Completed

VERBOSE_MASK: LOG_SFS (0x00002000)

DESCRIPTION: This indicates that an ECHO diagnostic has completed.

SEVERITY LEVEL: Debug

MESSAGE: ECHO diagnostic completed

ACTION: No action needed, informational.

MSG_ID: 1312 Warning: ECHO Diagnostic Failed

VERBOSE_MASK: LOG_SFS (0x00002000)

DESCRIPTION: This indicates that an ECHO diagnostic has failed to return a positive result. This could indicate a connectivity problem with your FC network.

SEVERITY LEVEL: Warning

MESSAGE: ECHO diagnostic failed

ACTION: Check your network connections. If problems persist report these errors to system administrator.

MSG_ID: 1313 Debug: BIU Diagnostic Completed

VERBOSE_MASK: LOG_SFS (0x00002000)

DESCRIPTION: This indicates that a BIU diagnostic has completed.

SEVERITY LEVEL: Debug

MESSAGE: BIU diagnostic completed

ACTION: No action needed, informational.

MSG_ID: 1314 Error: BIU Diagnostic Failed

VERBOSE_MASK: LOG_SFS (0x00002000)

DESCRIPTION: This indicates that a BIU diagnostic has failed to return a positive result. This is usually caused by an adapter hardware problem.

SEVERITY LEVEL: Error

MESSAGE: BIU diagnostic failed

ACTION: Report this error to Technical Support.

MSG_ID: 1315 Debug: POST Diagnostic Completed

VERBOSE_MASK: LOG_SFS (0x00002000)

DESCRIPTION: This indicates that a POST diagnostic has completed.

SEVERITY LEVEL: Debug

MESSAGE: POST diagnostic completed

ACTION: No action needed, informational.