Using the CLI Client

The CLI Client is a console application named hbacmd. Each time you run this application from the command line, a single operation is performed.

The first parameter of this command is the requested operation. When the specified operation is completed, the command prompt is displayed. Most operations retrieve information about an entity on the SAN and display that information on the console.

Most of the CLI Client commands require one or more additional parameters that specify the nature of the command. A parameter used by many hbacmd commands specifies the World Wide Port Name (WWPN) of the HBA that is the target of the command. For example, the following command shows the port attributes for the HBA with the specified WWPN:

/usr/sbin/hbanyware/hbacmd portattrib 10:00:00:00:c9:20:20:20

hbacmd can be run in out-of-band mode by making the first argument h=<host>. For example:

/usr/sbin/hbanyware/hbacmd h=cp-hp5670 listhbas /usr/sbin/hbanyware/hbacmd h=138.239.91.121 listhbas

Syntax Rules

The syntax rules for the HBAnyware utility Command-Line Interface (hbacmd) are as follows:

All commands and their arguments are NOT case sensitive.

The requested operation must contain at least three characters, or as many as needed to distinguish it from any other operation.

Whenever a WWPN is specified, individual fields are separated by colons (:) or spaces ( ). When using space separators, the entire WWPN must be enclosed in quotes (").

All hbacmd inputs must be in hexadecimal format. The only exceptions are the cycle-counts used in some of the diagnostic commands.

Out-of-Band Access

Out-of-band (OOB) access enables you to access HBAs via their IP-address or by the name of the host on which they reside. Since HBAs may exist on a host but not be a part of a FC network, they will not appear during normal in-band discovery. Thus, OOB access enlarges the number of HBAs that can be queried or modified.

Note: A local host cannot be accessed out-of-band.

OOB access via hbacmd uses an additional parameter on the command line. The parameter must be the first parameter in the list, coming immediately after hbacmd. The remaining parameters are those documented for each operation.

Note: You can also access an in-band HBA via its OOB address.

The format of the OOB parameter is: h={<IPAddress> <host-name>}

Some examples are:

h=128.239.91.88 h=cp-compaq8000

The following lists all HBAs running on the host with a specified IP address:

hbacmd h=128.239.91.88 listHBAs