Troubleshooting
Install
ID/error LED green LED
Power indicator bicolor LED
Connecting External Devices
Management Blade Configuration
Before Setting Up
Serial port connector
Mounting the Assembly Kit
Single-phase or Phase input
Page 1
Image 1
PRIMERGY BX600 S3 Basic Unit
Operating Manual
Edition January 2009
Page 1
Page 2
Page 1
Image 1
Page 1
Page 2
Contents
Primergy BX600 S3 Basic Unit
Copyright and Trademarks
Comments… Suggestions… Corrections…
Certified documentation according to DIN EN ISO
Contents
Contents
Fibre Channel I/O Blades
Replacing a Fan in the Unit
Primergy BX600 S3 Basic Unit
Preface
Overview of the Documentation Preface
Overview of the Documentation
Concept and Target Group of this Manual
Additional Server Documentation
Further Sources of Information
Features Preface
Features
Server Capacity
Communication Interfaces
Features
KVM Blade
Management Blade
Ventilation
Power Supply
High Level of Availability and Failure Protection
Server Management
Service and Support
ServerView Installation Manager
Notational Conventions
Technical DataPreface
Technical Data
Electrical Data single power supply unit
Electrical Data basic unit without server blades
Certification
Weight
Mechanical Values
Environmental Conditions
Noise Level
Technical Data
Overview Installation Steps
Overview Installation Steps
Important Notes
Before Setting Up
Important Notes
Batteries
Other Important Notes
Components With Electrostatic-Sensitive Devices
FCC Class a Compliance Statement
CE Certificate
CE Certificate
Transporting the Basic Unit
Important Notes
Environmentally Friendly Product Design and Development
Environmental Protection
Environmental Protection
Symbols for electrical electronic devices
Local Contacts
Returning Batteries
Page
Installation Steps
Installing the Hardware
Installing the Hardware
Unpacking the Basic Unit
Unpacking the Basic Unit
Requirements of the Rack
Installing the System in the Rack
PRIMECENTER/DataCenter Rack
3rd-Party Rack
Installing the System in the Rack
Mechanical conditions BX600 S3
Mounting the support brackets
Mounting the Assembly Kit
Mounting the left carrier rail
Mounting the basic unit
Mounting/Removing the Basic Unit
Connecting External Devices
Connectors on the back of the basic unit
Connecting External Devices
PCI Cards with Cable at the Front
Cable Routing
Installing the Hardware
Connecting Cables
Instructions on Connecting and Disconnecting Cables
Disconnecting Cables
Connecting the System to the Mains
Connecting the System to the Mains
Connecting the System to the Mains
Page
Preparation for Use and Operation
Operating and Indicator Elements
Operating and Indicator Elements of the Basic Unit
Power indicator bicolor LED
System power ON/OFF button
Preparation for Use and Operation
Front identify/Fault indicator amber LED
Front identify button
Rear
Rear identify/Fault indicator green LED1
Rear identify button1
Switching on the Basic Unit Basic Unit is Powered OFF
Switching the Basic Unit ON/OFF
Switching OFF the Basic Unit System is Powered on
After power failure
Switching the Blade Server ON/OFF
Switching the Server Blades ON/OFF
Specified switch-ON time/switch-OFF time
Pre-Configuration Requirements
Management Blade Configuration
Initial Configuration via Serial Connection to Client
Cabling the System
Vcaution
Management Blade Configuration
Enter 1 to call up the Management Agent Information menu
Management Agent Information menu
Agent NIC Duplex Mode menu
Updating System Components
Updating the Server Blade Firmware Bios and BMC
Proceed as follows
Updating the server blade Bios via the web interface
Updating the server blade BMC via the web interface
Updating the Management Blade Firmware
Updating the management blade firmware via the web interface
Updating the Switch Blade Firmware
⎜ Press Ctrl-Q Return Console Menu
Removing an operation code image file
Click Transfer from Server
Page
Preventing Unauthorized Bios Setup Calls
Bios Setup Security Functions
Preventing Unauthorized System Access
Preventing Unauthorized Boot Process
Page
Primergy BX620 S3/S4 2-way server blade BX600 S3
Server Blades
Primergy BX630 scalable server blade 4-way configuration
Server Blades
Fitting rules
Adding a Server Blade to the System Server Blades
Adding a Server Blade to the Basic Unit
Removing the Dummy Module
Adding a Server Blade to the System
BX600 S3
Inserting the server blade
Final engaging of the locking mechanism
Removing the Server Blade
Ethernet LAN I/O Blades
Ethernet Switch Blade SB9 6x1Gbit
Gbit Ethernet LAN Switch Blade SB9 6x1Gbit
Ethernet I/O Blades
GbE Intelligent Blade Panel IBP 10/6
Ethernet Switch Blade SB9 6x1 Gbit + 2x10 Gbit
Gbit Ethernet LAN Switch Blade SB9 6x1 Gbit + 2x10 Gbit
Ethernet I/O Blades
Ethernet Switch Blade SB9F 12x1 Gbit
Gbit Ethernet LAN Switch Blade SB9F 12x1 Gbit
GbE Intelligent Blade Panel IBP 30/12
Ethernet Switch Blade SB9F 12x1 Gbit
Cisco Catalyst Blade Switch
Cisco Catalyst Blade Switch
Cisco Catalyst Blade Switch
Gbit Switch Blade 10/2
10 Gbit Switch Blade 10/2
Gbit Switch Blade 10/2
Ethernet LAN Pass-Thru-Blade
NET2 NET4 NET1 NET3
Port Assignment of the LAN Switch Blades
LAN port assignment with ten 2-way server blades
Port Assignment
BX620 S4
LAN port assignment with five 4-way server blades
Configuration with Five 4-way Server Blades
Way Blade Server Way server
Installing an I/O Blade
Installing an I/O Blade
Remove the dummy module from the slot
Disengaging the I/O blade
Inserting the I/O Blade
Inserting the I/O blade a = green touch point
Removing the I/O Blade
Page
Fibre Channel I/O Blades
Gbit FC Switch Blade SW4016 4D
4/4 Gbit Fibre Channel Switch Blade Brocade SilkWorm 4016 4D
FC switch blade status display 2-color LED
IThe LED might also blink while testing
Gbit FC Switch Blade SW4016
2/4 Gbit Fibre Channel Switch Blade Brocade SilkWorm
Fibre Channel I/O Blades
2 Gbit Fibre Channel Pass-Thru Blade
Gbit FC Pass-Thru Blade
4 Gbit Fibre Channel Pass-Thru Blade
Inserting a Fibre Channel SFP module
Fibre Channel SFP Module
Removing an SFP Module
Fibre Channel SFP Module
NET4 NET3
Port Assignment
Fabric port assignment with 2-way server blades
Configuration with Ten 2-way Server Blades
Operating Manual 111
FC I/O blade installation
FC I/O Blade Installation
Management blade slots
Management Blade
LAN link indicator green LED Lights green The LAN is linked
Serial port connector
Control and Connection Panel
I2C connector
LAN active indicator amber LED
Failure indicator amber LED
Master indicator green LED
Exchanging a Management Blade
Exchanging a Management Blade
Removing the Management Blade
Operating Manual 117
Removing the management blade
KVM Blade Standard Version
KVM Blade
KVM connector
ID/error LED green LED
KVM Blade Standard Version
Control Panel of the KVM Blade Standard Version
Control Panel of the Adv. KVM Blade
11.2 Adv. KVM Blade
LAN activity indicator green LED
Rear ID/error LED green LED
LAN connection indicator orange LED
Adv. KVM Blade
Digital KVM Blade
ID indicator
Power indicator
Digital KVM Blade
Control panel of the digital KVM blade
PSU4 PSU3 PSU2 PSU1
Power Supply Concept
Basic unit with a single phase input
Single basic unit with a single phase input
Single basic unit with a 3-phase input
Power Supply Concept Single basic unit with a 3-phase input
UPS
Single basic unit with a single UPS
Single basic unit with two UPSs
Power Supply Concept Single basic unit with two UPSs
Two basic units with two UPSs
Single-phase or Phase input
Power Supply Concept
Power Supply Units
Fault display amber LED
Power Supply Units
Mains power supply display green LED
On/off display green LED
Replacing a Power Supply Unit
Disengaging the power supply unit a = green touch point
Operating Manual 135
Removing the PSU
Adding a Power Supply Unit
Operating Manual 137
Page
FAN1 FAN2
Ventilation Concept
Fan Unit
Fan Unit
Fan 1 LEDs Fan 2 LEDs Fan condition
Ventilation Concept
Replacing the Fan Unit
Removing the fan unit
Replacing a Fan in the Unit
Page
System Power LED Remains Unlit
Troubleshooting and Tips
Wrongly connected power cables
Power supply overloaded
Troubleshooting and Tips
Front or Rear Identify/Fault LED Blinks Amber
One of the power supply units fails
Switch blade fails
Screen Remains Dark
System Switches Itself OFF
No Screen Display or Display Drifts
Flickering Stripes on the Monitor Screen
No Mouse Pointer Displayed On the Screen
Monitor does not support the set horizontal frequency
Floppy Disk Cannot Be Read/Written
Server Blade Does Not Boot
Time and Date Are Not Correct
Defective Drive
BX600 S3
Abbreviations
Abbreviations
ISCSI
Post
USV
Page
Primecenter Rack
Related Publications
158 Operating Manual
Operating Manual 159
Page
EMC
Index
LED
Index
LAN
Unpacking
Top
Page
Image
Contents