Server Blades

Adding a Server Blade to the System

￿

!

Figure 30: Removing a server blade dummy module

ÊRelease the locking mechanism of the ejecting handles by pressing the touch points on the inside of both handles (1) simultaneously. The ejecting handles of the dummy module will be disengaged.

ÊSwing up the upper handle and swing down the lower handle simultaneously

(2)until the locking mechanism of the dummy module disengages and the dummy module ejects.

ÊRemove the dummy module completely from the slot (3).

VCAUTION!

Keep the dummy module for future use. If the server blade is removed and not replaced with a new server blade, then the dummy module must be reinstalled for cooling, to comply with the applicable EMC regulations (regulations on electromagnetic compatibility) and for fire protection.

Installation is the same as for the server blade (see “Inserting the Server Blade” on page 76).