GR2000 Installation Guide

Switch and LED indication

Table 3-3 RMP switch and function of LED indications

Name of switch

Switch or LED

Status

Content

and LED

 

 

 

STATUS (RM)

LED: Green/

Shows the

Green: Operable operation

 

Yellow/ Red

operating

Yellow: Blocked

 

 

condition of RM.

Green blinking: Under preparation (being started up.)

 

 

 

Red: Fault or shutdown

 

 

 

Extinguished: Operation not possible (Including the device

 

 

 

power supply being turned off)

 

 

 

 

POWER

LED: Green

Shows the state of

Green: Voltages of 5V and 3.3V of RMP are normal.

 

 

power supply

Extinguished: Voltages of 5V and 3.3V of RMP are not the

 

 

turned on or off.

specified voltage.

 

 

 

(Fault in power supply unit or RMP board, or power supply

 

 

 

switch in device is turned off, or AC power is not fed.)

 

 

 

 

READY

LED: Green

Shows the

Green: Operable operation

 

 

operable condition

Extinguished: Operation not possible (Including the device

 

 

of the device.

power supply being turned off)

 

 

 

 

ERROR

LED: Yellow

Shows partial fault

Yellow: Partial fault has been developed in the device.

 

 

in the device.

Extinguished: Occurrence of partial fault is not detected.

 

 

 

(Including the device power supply being turned off.)

 

 

 

 

ALARM

LED: Red

Shows

Red: Partial fault has occurred in the device.

 

 

occurrence of fault

Extinguished: Operation possible. (Including the device

 

 

in the device.

power supply being turned off.)

 

 

 

 

POST DISP

LED: Green

Shows the state

Green: Shows the state that STATUS CODE (7 seg) is

 

 

that STATUS

indicating the initial diagnosis code of RM-CPU.

 

 

CODE is

Extinguished: Shows that STATUS CODE (7 seg) is

 

 

indicating the

indicating the contents of FAULT CODE. (Including the

 

 

initial diagnosis

device power supply being turned off.)

 

 

code of RM-CPU.

 

 

 

 

 

STATUS CODE

7 seg for

7 seg. Decimal

Green: Indicates the device state code for 00~99. (Code

 

indicating the

and two digits.

contents differ by lighting of POST DISP LED.)

 

device

 

Extinguished: Non-indication. (Including the device power

 

condition.

 

supply being turned off.)

 

 

 

 

ACCESSO

LED: Green

Shows the state of

Blinking: MC card zero being accessed. (Memory card

 

 

MC card being

take-out is prohibited.)

 

 

zero.

Extinguished: MC card zero being idle. (Memory card may

 

 

 

be put in or taken out.)

 

 

 

 

ACCESS 1

LED: Green

Shows the state of

Blinking: MC card one being accessed. (Memory card

 

 

MC card being

take-out is prohibited.)

 

 

one.

Extinguished: MC card one being idle. (Memory card may

 

 

 

be put in or taken out.)

 

 

 

 

STATUS (RP)

LED: Green/

Shows the

Green: Operable operation

 

Yellow/ Red

operating

Yellow: Blocked

 

 

condition of RM.

Green blinking: Under preparation (being started up.)

 

 

 

Red: Fault or shutdown

 

 

 

Extinguished: Operation not possible (Including the device

 

 

 

power supply being turned off.)

 

 

 

 

STATUS (NIFE)

LED: Green/

Shows the

Green: Operable operation

 

Yellow/ Red

operating

Yellow: Blocked

 

 

condition of XIF2

Green blinking: Under preparation (being started up.)

 

 

(built-in Ethernet).

Red: Fault or shutdown

 

 

 

Extinguished: Operation not possible (Including the device

 

 

 

power supply being turned off)

 

 

 

 

LNK/ACT

LED: Green

 

Green: Ring pulse of 10BASE-T or 100BASE-TX is being

 

 

 

established.

 

 

 

 

3-6

GR2K-GA-1002

 

Rev. 6.03

Page 108
Image 108
Hitachi GR2000 Status RM, Power, Ready, Error, Alarm, Post Disp, Status Code, Accesso, Status RP, Status Nife, Lnk/Act