GR2000 Installation Guide
Switch and LED indication
Table
Name of switch | Switch or LED | Status | Content |
and LED |
|
|
|
STATUS (RM) | LED: Green/ | Shows the | Green: Operable operation |
| Yellow/ Red | operating | Yellow: Blocked |
|
| condition of RM. | Green blinking: Under preparation (being started up.) |
|
|
| Red: Fault or shutdown |
|
|
| Extinguished: Operation not possible (Including the device |
|
|
| power supply being turned off) |
|
|
|
|
POWER | LED: Green | Shows the state of | Green: Voltages of 5V and 3.3V of RMP are normal. |
|
| power supply | Extinguished: Voltages of 5V and 3.3V of RMP are not the |
|
| turned on or off. | specified voltage. |
|
|
| (Fault in power supply unit or RMP board, or power supply |
|
|
| switch in device is turned off, or AC power is not fed.) |
|
|
|
|
READY | LED: Green | Shows the | Green: Operable operation |
|
| operable condition | Extinguished: Operation not possible (Including the device |
|
| of the device. | power supply being turned off) |
|
|
|
|
ERROR | LED: Yellow | Shows partial fault | Yellow: Partial fault has been developed in the device. |
|
| in the device. | Extinguished: Occurrence of partial fault is not detected. |
|
|
| (Including the device power supply being turned off.) |
|
|
|
|
ALARM | LED: Red | Shows | Red: Partial fault has occurred in the device. |
|
| occurrence of fault | Extinguished: Operation possible. (Including the device |
|
| in the device. | power supply being turned off.) |
|
|
|
|
POST DISP | LED: Green | Shows the state | Green: Shows the state that STATUS CODE (7 seg) is |
|
| that STATUS | indicating the initial diagnosis code of |
|
| CODE is | Extinguished: Shows that STATUS CODE (7 seg) is |
|
| indicating the | indicating the contents of FAULT CODE. (Including the |
|
| initial diagnosis | device power supply being turned off.) |
|
| code of |
|
|
|
|
|
STATUS CODE | 7 seg for | 7 seg. Decimal | Green: Indicates the device state code for 00~99. (Code |
| indicating the | and two digits. | contents differ by lighting of POST DISP LED.) |
| device |
| Extinguished: |
| condition. |
| supply being turned off.) |
|
|
|
|
ACCESSO | LED: Green | Shows the state of | Blinking: MC card zero being accessed. (Memory card |
|
| MC card being | |
|
| zero. | Extinguished: MC card zero being idle. (Memory card may |
|
|
| be put in or taken out.) |
|
|
|
|
ACCESS 1 | LED: Green | Shows the state of | Blinking: MC card one being accessed. (Memory card |
|
| MC card being | |
|
| one. | Extinguished: MC card one being idle. (Memory card may |
|
|
| be put in or taken out.) |
|
|
|
|
STATUS (RP) | LED: Green/ | Shows the | Green: Operable operation |
| Yellow/ Red | operating | Yellow: Blocked |
|
| condition of RM. | Green blinking: Under preparation (being started up.) |
|
|
| Red: Fault or shutdown |
|
|
| Extinguished: Operation not possible (Including the device |
|
|
| power supply being turned off.) |
|
|
|
|
STATUS (NIFE) | LED: Green/ | Shows the | Green: Operable operation |
| Yellow/ Red | operating | Yellow: Blocked |
|
| condition of XIF2 | Green blinking: Under preparation (being started up.) |
|
| Red: Fault or shutdown | |
|
|
| Extinguished: Operation not possible (Including the device |
|
|
| power supply being turned off) |
|
|
|
|
LNK/ACT | LED: Green |
| Green: Ring pulse of |
|
|
| established. |
|
|
|
|
| |
| Rev. 6.03 |