NWT3-1C switch and function of LED indication

3-62

Connector specifications for NWT3-1C

3-62

NEW1-8 switch and function of LED indications

3-63

NEW1-8 switch and function of LED indication

3-64

Connector Specification for NWE1-8

3-64

POW Models

3-65

Locations for Components of POW-M100H and POW-M100HA

3-68

Locations for Components of POW-M200H and POW-M200HA

3-69

Locations for Components of POW-MDCH and POW-MDCHA

3-70

Locations for Components of POW-L200H and POW-L200HA

3-71

Locations for Components of POW-LDCH and POW-LDCHA

3-72

V.24/V.35/X.21 Interface Cable Selection

3-76

Restrictions on cable length according to line speed

3-78

LAN Interface Cable Selection

3-85

Pin arrangement on the device side (10MBASE/100MBASE interface)

3-86

Pin arrangement on the device side (10MBASE/100MBASE interface)

3-86

Optical Interface Specifications for 100BASE-FX Multimode Connection

 

(In this case core/clad diameter is 62.5/125 µm.)

3-87

Optical Interface Specifications for 100BASE-FX and 1000BASE-LH Single-Mode

 

Connections

3-88

Customer Responsibility WAN Interface Cable Selection

3-90

Pin arrangement on the device side (1.430 interface)

3-91

Pin arrangement on the device side (primary group (1.431) interface)

3-92

Pin arrangement on the device side and DSU side (primary group (1.431) interface

3-94

Optical Interface Specifications for OC-48c/STM-16 (POS) Single-Mode Connections

3-97

Optical Interface Specification for NWOC48-1S8/1A8

3-98

ATM Interface Cable Selection

3-99

Specifications of Optical Interface

3-100

Specifications of Optical Interface

3-101

Chapter 4 - Precautions in Planning Installation

4-1

The operation terminal conditions

4-2

The cross cable specifications show the connection specifications for the cross cables

4-3

Modem setting

4-3

The RP mounting conditions by each model

4-7

RP mounting conditions when using GR2000-10H and GR2000-20H in 100V AC

4-8

Applicable Types and Quantities of RPs by Router Model

4-8

Quantities of NIFs by Router Model

4-9

BCU Memory Increment by Router Model

4-11

RP Memory Increment by RP Type

4-11

100BASE-TX Line Accommodation

4-11

100BASE-FX Line Accommodation

4-12

WAN Line Accommodation per NIF at Line Speed of up to 6 Mbps

4-12

WAN Line Accommodation per RP-A1 at Line Speed of up to 6 Mbps

4-12

WAN Line Accommodation per RP-D at Line Speed of up to 6 Mbps

4-13

E3 Multiplex Line Accommodation per RP-D at Line Speed of 34 Mbps

4-13

T3 Multiplex Line Accommodation per RP-D at Line Speed of 45 Mbps

4-13

WAN (ISDN) Line Accommodation Limit

4-14

WAN (Overload) Line Accommodation Limits

4-14

Multilink Overload Line Accommodation Limit: Inter-RP, Full Duplex, 64kbps Bundled

4-15

Multilink Overload Line Accommodation Limit: Inter-RP, Half Duplex, 64kbps Bundled

4-15

Multilink Overload Line Accommodation Limit: Intra-RP, Full Duplex, 64kbps Bundled

4-15

Multilink Overload Line Accommodation Limit: Intra-RP, Half Duplex, 64kbps Bundled

4-15

Restriction on Aggregate Line Speed for GR2000-4S and GR2000-4

4-17

Speed Conversion of Full-Size NIF

4-18

 

 

GR2K-GA-1002

li

Rev. 6.03

 

Page 51
Image 51
Hitachi GR2000 manual This case core/clad diameter is 62.5/125 µm, Operation terminal conditions