Table 5-7 shows typical power consumption and heat dissipation figures. Each configuration assumes the maximum configuration.

Table 5-7 Typical Power Consumption and Heat Dissipation Figures

 

 

 

 

 

 

 

Configuration

Input Power Condition

Power

Heat dissipat

 

 

 

 

Consumption (A)

(W)

 

Voltage

Frequency

 

 

 

 

 

 

 

 

 

 

GR2000-2S

100 Vac

50/60 ± 1 Hz

2

200

 

 

 

 

 

 

 

GR2000-4S

100 Vac

50/60 ± 1 Hz

3

260

 

 

 

 

 

 

 

 

 

200

Vac

50/60 ± 1 Hz

3

260

 

 

 

 

 

 

 

GR2000-6H

100 Vac

50/60 ± 1 Hz

12

1140

 

 

 

 

 

 

 

 

 

200

Vac

50/60 ± 1 Hz

12

1140

 

 

 

 

 

 

 

 

–48 Vdc

12

950

 

 

 

 

 

 

 

 

GR2000-10H with either redundant

100

Vac

50/60 ± 1 Hz

12

1080

 

or non-redundant POW(s)

 

 

 

 

 

 

200

Vac

50/60 ± 1 Hz

8

1350

 

 

 

 

 

 

 

 

 

 

–48 Vdc

27

1170

 

 

 

 

 

 

 

GR2000-20H with either redundant

200 Vac

50/60 ± 1 Hz

14

2340

 

 

 

 

 

 

 

 