Hitachi GR2000 manual Line 5 Line 4 .+0#%6.+064 4 LINE8 1 8 Line 0 .+0

Models: GR2000

1 410
Download 410 pages 45.58 Kb
Page 129
Image 129

Component Details

Be careful when connecting the cables attached to VX-8 to the devices that the connector insertion faces are reversed between the lower side connectors (LINE 0, LINE 1, and LINE 4, LINE 5) and the upper side connectors (LINE 2, LINE 3, and LINE 6, LINE 7).

 

LINE 7

LINE 6

LINE 3

LINE 2

LINE 5

LINE 4

 

 

100-pin high-density connecto

 

 

 

 

The cables attached to VX-8 have a length of 1 m.

The cables attached to VX-8

LINE 1

LINE 0

50-pin half-pitch connector

50-pin half-pitch connector equivalent to that for NWVX-4

50-pin half-pitch connector

The existing interface cables (V.24, V.35, X.21)

LINE 7

LINE 6

LINE 3

LINE 2

7

LINE 5 LINE 4 .+0')#%6;￿.+0'￿6￿￿'44LINE8￿￿￿￿1 8￿￿￿￿LINE:￿￿￿0 .+0'

:890￿

When connecting the cables attached to VX-8 to the devices, tighten the connectors lightly to the standard torque of 1.5 kgf/cm by using a screw driver (a small sized screw driver is recommended). Be extremely careful not to over-tighten(which may cause the bolts to break).

100-pin high-density connector

Small screw driver is recommended

Figure 3-27 Relationship between connection of cables supplied with VX-8 and LINE

#65number

￿￿￿￿￿￿￿

￿￿￿￿￿￿￿

 

 

 

GR2K-GA-1002

 

3-27

Rev. 6.03

 

 

Page 129
Image 129
Hitachi GR2000 manual Line 5 Line 4 .+0#%6.+064 4 LINE8 1 8 Line 0 .+0