Hitachi GR2000 Maximum Number of Dynamic and Static Entries, Maximum Limit Total Dynamic Static

Models: GR2000

1 410
Download 410 pages 45.58 Kb
Page 231
Image 231

maximum number of dynamic entries and static entries. Use the device so that t total value of dynamic and static entries does not exceed the maximum number o entries for the device. Using the device at the maximum entry capacity requires mounted memory amount shown in "(3) Minimum required memory".

Table 4-44 Maximum Number of Dynamic and Static Entries

Item

 

Maximum Limit

 

 

 

 

 

 

 

 

Total

Dynamic

Static

 

 

 

 

 

IP unicast route entries

2,000,000/router

2,000,000/router

3,000/router

 

 

 

 

 

IP multicast route entries

10,000/router**

10,000/router**

-

 

 

 

 

 

 

ARP entries

4,096/RP*

4,096/RP*

4,096/router

 

 

 

 

 

IPX routing table entries

1,000/router

1,000/router

200/router

 

 

 

 

 

IPX ARP entries

256/router

-

256/router

 

 

 

 

 

Bridge filtering database entries

2,000/router

2,000/router

500/router

 

 

 

 

 

* Total maximum per router is determined by number of installable RPs for the target router model. ** It will be 1000/device in the case of PIM-SM.

Page 231
Image 231
Hitachi GR2000 manual Maximum Number of Dynamic and Static Entries, Maximum Limit Total Dynamic Static