GR2000 Installation Guide

Table 3-27 NEW1-8 switch and function of LED indication

ACT

T/R

 

 

 

Line state

 

 

 

indication in

LINE ERR

LOOP

Line state

Detail of state

State as seen by SXMP

MMI and

(*1)

(*1)

 

 

 

 

 

 

browser

 

 

 

 

 

 

 

 

 

 

 

--

(*3)

Being initialized.

 

Being initialized (3).

initialize

 

 

 

 

 

 

G

(*3)

Being operated

In normal

In standby (3).

active up

 

 

 

operation.

 

 

 

 

 

 

 

 

Y

(*3)

 

Line fault being

In operation (line fault being

active down

 

 

 

occurred.

occurred (8).

 

 

 

 

 

 

 

G

(*3)

Line test.

 

Line being tested (9).

test

 

 

 

 

 

 

--

--

In fault.

 

In fault (4).

fault

 

 

 

 

 

 

--

--

Command being

 

In maintenance (10).

closed

 

 

blocked.

 

 

 

 

 

 

 

 

 

--

--

Not used.

Configuration

Not used.

unused

 

 

 

definition not set

Configuration definition not

 

 

 

 

yet

set yet. (10)

 

 

 

 

 

 

 

--

--

Configuration definitions

 

Configuration definitions not

mismatch

 

 

not agreed.

 

agreed. (11)

 

 

 

 

 

 

 

(*1): G: Lights in green, Y: Lights in yellow, -: Goes off

(*2): Meaning and value of SMNP private MIB and gr2kPhysLineOperStatus

(*3): The T/R LED lights and goes off by H/W. In lighting conditions, this LED lights in green when the logical value of send and receive data is "0". The LED lights in green when lighting conditions are detected irrespective of the line state.

*

Note: When making connection with the cable having come off, repeat cancellation of the LED

and lighting up of the ERR (or ACT) LED to retry the CLOSE/OPEN operation of the line.

Precautions when connecting NWVX-8

Relationship between connection of cables supplied with VX-8 and LINE number

￿NWVX-8 is supplied with the cables attached to VX-8.

Connect the cables attached to VX-8 (100-pin high-density connector) as shown below.

The tips of the cables attached to VX-8 have connecting sections for the same 50-pin half-pitch connectors (LINE 0 to LINE 7) as in NWVX-4.

3-26

GR2K-GA-1002

 

Rev. 6.03

Page 128
Image 128
Hitachi GR2000 manual Precautions when connecting NWVX-8, Line state, Indication