Table 2-4 RP Specifications

RP name

Specification

Note

 

 

 

RP-A1

Backup, QoS/Diff-serv, and multicasting

GR2000-2S: Not

 

Packet transfer rate: Approx. 1M packets/s

mountable

 

MS = 32MB (standard) - 96MB (max)

 

 

 

 

RP-DV

RP-DV is a routing processor to which the label stack H/W transfer function has

GR2000-4S,2S:

 

been enhanced.

Not mountable

 

Packet transfer rate: Approx. 4M packets/s

GR2000-10,20:

 

MS = 128MB (fixed)

Mountable with

 

• The packet transfer engine is commonly used for transmission and reception.

some limitations

 

• Routing retrieval engines are mounted exclusively for transmission and

(*1)

 

reception, respectively.

 

 

• The mounted processor is MIPS RM7000 250Mhz.

 

 

 

 

RP-D

In addition to the RP-A1’s features, MPLS and Tag VLAN coupling

GR2000-2S: Not

 

Packet transfer rate: Approx. 1M packets/s

mountable

 

MS = 64MB (standard) - 128MB (max)

GR2000-4S:

 

• Packet transfer engine is used commonly for transmission and reception.

Mountable with

 

• Routing retrieval engine is used commonly for transmission and reception.

some feature

 

• The mounted processor is MIPS RM7000 250Mhz.

limitations (*2)

 

 

 

RP-C

RP-C is a routing processor to accommodate high-speed lines including OC-48c,

GR2000-4S, -2S:

 

which has a packet processing performance about four times greater than that of

Not mountable

 

RPA1.

GR2000-10, -20:

 

GR2000 IPv6 compatible

Separate price

 

Has RP-C function

quote

 

IPv6, IPv4 dual stack

 

 

Packet transfer rate: 4.0Mpps (IPv4)

 

 

(Full duplex)2.6Mpps (IPv6)

 

 

MS = 128MB (standard) - 256MB (max)

 

 

• Packet transfer engines are mounted exclusively for transmission and reception,

 

 

respectively.

 

 

• Routing retrieval engines are mounted exclusively for transmission and

 

 

reception, respectively.

 

 

• The mounted processor is MIPS RM7000 250Mhz.

 

 

 

 

2-32

GR2K-GA-1002

 

Rev 6.03

Page 88
Image 88