Hitachi GR2000 manual Status, EMA Suppress

Models: GR2000

1 410
Download 410 pages 45.58 Kb
Page 114
Image 114

GR2000 Installation Guide

Switch and LED indication

Table 3-8 RM-IO switch and function of LED indications

Name of switch

Switch or LED

Status

Content

and LED

 

 

 

STATUS

LED: Green/

Shows the

Green: Operable operation

 

Yellow/ Red

operating

Yellow: Blocking and cock insertion and removal possible.

 

 

condition of RM.

Green blinking: Under preparation (being started up.)

 

 

 

Red: Fault or shutdown

 

 

 

Extinguished: Operation not possible (Including the device

 

 

 

power supply being turned off)

 

 

 

 

EMA SUPPRESS

LED: Yellow

Shows the state of

Yellow: If both of the operation and standby systems or

(GR2000-4S)

 

EMA SUPPRESS

only the operation system are lit, it shows that the system

 

 

key, and the

is in switching suppression state according to the

 

 

system switching

instructions of turning the operation system EMA

 

 

suppression state.

SUPPRESS switch on or EMA SUPPRESS by means of

 

 

 

software. If only the standby system is lit, since it shows

 

 

 

that the EMA SUPPRESS switch of the standby system is

 

 

 

turned on, keep the switch turned off. In this case, the

 

 

 

system switching is not suppressed.

 

 

 

Extinguished: Shows that it is not in the system switching

 

 

 

suppression state. (Including the device power supply

 

 

 

being turned off.)

 

 

 

 

ACTIVE

LED: Green

Shows the state of

Green: Shows the state of operation. (Lights up

(GR2000-4S)

 

operation/standby

continuously when not duplicated.)

 

 

of the duplicated

Extinguished: Shows the standby state. (Including the

 

 

section.

device power supply being turned off.)

 

 

 

 

POWER

LED: Green

Shows the state of

Green: Voltages of 5V and 3.3V of RMP are normal.

 

 

power supply

Extinguished: Voltages of 5V and 3.3V of RMP are not the

 

 

turned on or off.

specified voltage. (Fault in power supply unit or RMP

 

 

 

board, or power supply switch in device is turned off, or AC

 

 

 

power is not fed.)

 

 

 

 

READY

LED: Green

Shows the

Green blinking: Operable operation

 

 

operable condition

Extinguished: Operation not possible (Including the device

 

 

of the device.

power supply being turned off)

 

 

 

 

ERROR

LED: Yellow

Shows partial fault

Yellow: Partial fault has been developed in the device.

 

 

in the device.

Extinguished: Occurrence of partial fault is not detected.

 

 

 

(Including the device power supply being turned off.)

 

 

 

 

ALARM

LED: Red

Shows

Red: Partial fault has occurred in the device.

 

 

occurrence of fault

Extinguished: Operation possible. (Including the device

 

 

in the device.

power supply being turned off.)

 

 

 

 

POST DISP

LED: Green

Shows the state

Green blinking: Shows the state that STATUS CODE (7

 

 

that STATUS

seg) is indicating the initial diagnosis code of RM-CPU.

 

 

CODE is

Extinguished: Shows that STATUS CODE (7 seg) is

 

 

indicating the

indicating the contents of FAULT CODE. (Including the

 

 

initial diagnosis

device power supply being turned off.)

 

 

code of RM-CPU.

 

 

 

 

 

STATUS CODE

7seg: Green

7 seg for

Green blinking: Indicates the device state code for 00~99.

 

 

indicating the

(Code contents differ by lighting of POST DISP LED.)

 

 

device condition.

Extinguished: Non-indication. (Including the device power

 

 

7 seg. Decimal

supply being turned off.)

 

 

and two digits.

 

 

 

 

 

ACCESS 0

LED: Green

Shows the state of

Blinking: MC card zero being accessed. (Memory card

 

 

MC card being

take-out is prohibited.)

 

 

zero.

Extinguished: MC card zero being idle. (Memory card may

 

 

 

be put in or taken out.)

 

 

 

 