C 9.92

Operating Instructions

Operating the attachments

 

Operating the attachment variable pump* (adjustable

1

 

2

 

3

 

4

to 0-120 L)

 

 

 

 

 

 

 

The attachment variable pump is a device for operating at- tachments with a high hydraulic power requirement, eg a cylinder mower. The pump is operated electrically from the driver’s station.

-Connect the hydraulic hoses of the front or rear attachment to the return line (1) and supply line (2) quick couplings and, if necessary, to the black leakage oil coupling (4).

-Plug the coded plug of the attachment into the socket

(3) beside the quick couplings.

Bild_C992H_033

NOTE

Only one coded plug may be plugged in at the front or rear.

NOTE

If a new or unknown attachment is to be in- stalled, the cable harness for attachment encoding 204-80-72 must be used. The cor- rect encoding must be determined after con- sultation with the manufacturer of the attach- ment and Holder.

* Option

153 146

105

Page 107
Image 107
Holder C 9.92 H operating instructions 105