Operating Instructions

C 9.92

Maintenance after the first 500 service hours

 

-

Refit the drain plug with a new sealing ring. Make sure

2

 

that the plug is tight.

 

 

-

Fill recommended hydraulic oil through the filler neck (2).

 

Filling quantity

approx. 45 L

 

-Check the oil level at the sight glass (3).

-Refit the filler neck cap.

-Start the engine. Operate the working hydraulic and steering systems.

NOTE

The hydraulic system is vented automatically.

-Shut off the engine and depressurize the hydraulic

system.3

-Check for leaks.

-Check the oil level at the sight glass (3). Add hydrau- lic oil if necessary.

Checking the engine valve clearances

-See page 203 of maintenance every 1000 service hours.

Bild_C992H_059

Bild_C992H_060