Operating Instructions

 

 

C 9.92

Malfunctions, causes, remedy

 

 

 

 

 

 

Malfunction

 

Cause

 

Remedy

 

 

 

No build-up of pressure

 

Slide valve in input plate is stuck

 

Remove, clean or plate replace the

 

 

(foreign particles)

 

slide valve

 

Strong flow rate fluctuation or too little

 

Low oil flow

 

Increase RPM, reduce consumption of

flow of priority flow valve I

 

 

 

2nd load

Troubleshooting also with Opus (Order No. 204-80-70) or PC software in the menu

Keyboard check: keys of the membrane keyboard.

Output functions: functions XO...Y3, check if box provides current for valves.

Hydraulic accumulator: functions of the hydraulic accumulator.

Specified value channel.

FCE1: Joystick functions.

Diagnosis of master inputs.

Diagnosis of BKN nodes.

152

153 146

Page 154
Image 154
Holder C 9.92 H operating instructions 152