Operating Instructions

 

 

 

 

 

C 9.92

Operation

 

 

 

 

 

 

 

 

 

 

 

 

The tractor is stationary.

 

 

 

 

 

 

1

 

2

 

 

3

 

-Set the fine adjustment knob (1) to 0.

-Set the program switch (2) to speed range 3 or 4.

-Adjust the PTO RPM with the hand throttle (3).

NOTE

The engine speed must be at least 1500 RPM as the control only begins to function at this RPM.

NOTE

You can also change the ground speed ranges while driving.

Bild_C992H_024

The speed ranges 3 and 4 will set a speed controlled by the power requirement of the PTO. This means, for example, that when the snow blower needs more power when meet- ing with higher resistance, the tractor will drive more slowly. When resistance decreases, the tractor will speed up to the preset speed. Range 4 is especially trimmed to particular applications.

-Release the parking brake.

-The ground speed is controlled with the fine adjust- ment knob (1).

64

153 146

Page 66
Image 66
Holder C 9.92 H operating instructions BildC992H024