C 9.92

Operating Instructions

Operating the attachments

 

NOTE

The attachment variable pump will attempt to maintain the oil flow rate specified by the attachment plug and potentiometer, even if the engine RPM drops.

Only when the maximum swash angle of the pump is reached will the oil flow be reduced when the RPM are reduced (refer to diagram).

ATTENTION

When the attachment is no longer in use, al- ways turn the pump off with the safety switch so that the hydraulic oil will not heat up un- necessarily.

Switching off the attachment variable pump

-Turn the safety switch (6) off. The indicator in the switch will extinguish.

NOTE

When you stop the engine without switching off the attachment variable pump, the pump will not start after the engine is started again (for safety reasons).

To start the attachment variable pump, you must set the rotary knob (5) to 0 and the turn the safety switch (6) off and on once.

S990 Variable pump flow

 

130

 

 

120

120 L/min

 

110

 

 

100

100 L/min

(L/min)

90

90 L/min

80

80 L/min

70

70 L/min

Flow

60

60 L/min

 

 

 

50

50 L/min

 

40

 

 

30

 

 

20

 

 

10

 

 

0

 

 

900

1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400 2500 2600

RPM Diesel engine (1/min)

Bild_S 990_031_GB

5 6

Bild_C992H_034

153 146

107

Page 109
Image 109
Holder C 9.92 H operating instructions Switching off the attachment variable pump, S990 Variable pump flow