Malfunctions, causes, remedy

 

 

 

 

 

 

Malfunction

 

Cause

 

Remedy

 

 

 

Joystick inoperative

 

Joystick locked

 

Release with Opus or PC software

 

 

Buttons defective

 

Determine fault with Opus, submit the

 

 

 

 

joystick for repair, or replace it

 

 

 

 

 

 

Membrane keyboard inoperative

 

Mechanically or electrically

 

Determine fault with Opus or PC

 

 

defective

 

software, replace membrane keyboard

 

 

 

 

and/or related printed circuit board

 

Simultaneous failure of many joystick

 

Power supply interrupted

 

Determine and eliminate the defect

and membrane keyboard functions

 

(3 separate positive cables, pin 05,

 

(cable breakage, contact problems in

 

 

23, 34)

 

the plug) Attention: Although voltage is

 

 

 

 

applied in the quiescent state, power

 

 

 

 

failure can result during operation

 

Functions operate too slowly or too

 

Flow rate limiting out of adjustment

 

Readjust with hash (#) key and joystick

fast

 

 

 

or Opus or PC software

 

 

Current value for a certain channel

 

Adjust from 800 to 1900 mA in

 

 

too low

 

"Channels" area with Opus or PC

 

 

 

 

software

 

4th control level on joystick

 

Special function activated with

 

Push the asterisk (*) key again

"malfunctioning"

 

asterisk (*) key

 

 

 

 

Joystick or membrane keyboard not

 

Bus cable is defective (Opus does

 

Make a connection or replace the

functioning

 

not indicate a connection)

 

cable