Item

Description

 

Selects whether to enable TC-BPDU guard.

 

When receiving topology change (TC) BPDUs, the device flushes its forwarding

 

address entries. If someone forges TC-BPDUs to attack the device, the device

tc-protection

will receive a large number of TC-BPDUs within a short time and frequently

flushes its forwarding address entries. This affects network stability.

 

 

With the TC-BPDU guard function, you can prevent frequent flushing of

 

forwarding address entries.

 

HP recommends not disabling this function.

 

Sets the maximum number of immediate forwarding address entry flushes the

tc-protection threshold

device can perform within a certain period of time after receiving the first

 

TC-BPDU.

 

 

Configuring MSTP on a port

1.From the navigation tree, select Network > MSTP.

2.Click the Port Setup tab.

Figure 181 MSTP configuration on a port

3.Configure MSTP for ports as described in Table 60, and then click Apply. Table 60 Configuration items

Item

Description

STP

Selects whether to enable STP on the port.

 

 

 

Sets the type of protection to be enabled on the port:

Protection

Not Set—No protection is enabled on the port.

 

Edged Port, Root Protection, Loop Protection—For more information, see Table 61.

 

 

 

195