Image Sensor Calibration

The precise location of the image sensor (camera) relative to the printheads is critical for edge-to-edge printing on rigid cut-sheet media. The Image Sensor Calibration determines this distance with precision.

Run this calibration after installing the printer for the first time, and whenever the camera height is changed (“Setting the Cam- era Height” on page 5-15) or the camera is replaced.

To calibrate the location of the image sensor:

1.Load media.

Load enough media (either roll-fed or cut-sheet) to print the small calibration pattern.

2.On the Front Page screen, press the  (Menu) key to enter the menu system.

3.From the control panel menu, press the ) key repeatedly to highlight Service Printer.

4.Press the  (Menu In) key.

5.From the Service Printer menu, press the ) key repeatedly until Image Sensor Calibration is highlighted.

6.Press the  (Menu In) key.

7.Press the " key to begin the calibration.

The calibration runs with no further action from you.

8.After the calibration completes, load or reload media and begin printing.