Calibrate the Service Station

Service station calibration enables you to properly align the ser- vice station wipers to the printheads. When properly aligned, the service station wipers should be centered on the printheads.

Setting the service station height should not be necessary unless the printhead height is changed by a large amount, or you notice that the service station wipers are not wiping the print- heads adequately.

Wipers

Printheads

Look here to calibrate

Adjustment screws

Fig. 5-6. Service station (cover removed for clarity)

1.On the Front Page screen, press the  (Menu) key to enter the menu system.

2.Press the ) key repeatedly to highlight Service Printer.

3.Press the  (Menu In) key display the Service Printer menu.

4.Press the ) key repeatedly to highlight Service Station.

5.Press the  (Menu In) key.

The control panel prompts you to confirm that you want to calibrate the service station.

Calibrate the Service Station

5-17