Setting Heater Temperatures

The are three heaters: a preheater, a platen heater, and post- heater. The postheater’s top and bottom zones can be set to dif- ferent temperatures. Optionally, the postheater can be turned off.

The heater temperatures can be set during the media load pro- cess (see “Loading Roll-Fed Media” on page 3-16), from the Media Wizard (see “Media Wizard” on page 3-44), or from the menu (see the following procedure).

1.From the control panel Front Page screen, press the  (Menu) key.

2.Press the ) key repeatedly to highlight Printer Settings.

3.Press the  (Menu In) key.

4.Press the ) key repeatedly to highlight Heater Temps Setting.

5.Press the  (Menu In) key.

The control panel displays a list of heater settings, num- bered from 0 to 10 and “Custom.”

6.Press the , or ) keys repeatedly to select a setting.

As you scroll through the settings, the temperature settings for each zone are shown at the bottom of the screen.

7.Press ! to select a setting, or  to cancel.

If you selected Custom, a list of heaters appears so you can change the settings for each of the heater zones.

If you selected any other setting, go to step 9.

8.Select a heater zone and set a new temperature.

If a Media Wizard type is currently loaded, the control panel asks whether to save the new setting in the Media Wizard for the currently loaded media.

Setting Heater Temperatures