HP 98SI, 72SI manual Table B-1. Actions and Warnings, Code, Message Cause What to Do

Models: 72SI 98SI

1 168
Download 168 pages 22.17 Kb
Page 156
Image 156

 

Table B-1. Actions and Warnings

 

Code, Message

Cause

What to Do

 

 

 

(CS) Capping Station

 

 

A-CS-1- Capping Station

Capping station is raised, and the car- Lower the capping station to allow

 

riage is not at the capping station.

the printheads to be capped, and to

 

 

prevent the carriage from crashing

 

 

into it.

 

 

 

A-CS-2 - Capping Station

Printheads are capped.

Uncap the printheads.

 

 

 

W-CS-1 - Capping Switch Disabled

The Capping Station Sensor has been

Enable the Capping Station Sensor in

 

disabled.

the Printer Settings menu.

 

 

 

(EI) Excess Ink Sensor

 

 

W-EI-1- Excess Ink Sensor Disabled

The Excess Ink Sensor has been dis-

Enable the Excess Ink Sensor in the

 

abled.

Printer Settings menu.

 

 

 

W-EI-2- Excess Ink Sensor

The Excess Ink Sensor is discon-

Ensure that the Excess Ink reservoir is

Disconnected

nected.

installed and the sensor is connected.

 

 

 

 

 

(HT) Heater

W-HT-[1 2 3 4 5 6 7 8 9 10 11] -

A heater or thermistor may be not

Heater Not Warming

functioning on the middle platen

 

heater (1-3), middle platen zone (4),

 

right platen heater (5), right platen

 

zone (6), left platen heater (7), left

 

platen zone (8), preheat heater (9),

 

postheater #1 (10), or postheater #2

 

(11).

Call your service provider to check wiring, heater, thermistors.

W-HT-[21 22 23 24 25 26 27 28 29 30

A heater has been turned off because

Wait for the heater to cool. If the tem-

31] - Heater Too Hot

its temperature has exceeded its

perature does not decrease, unplug

 

operational specification: middle

the printer, then restart it and lower

 

platen heater (21-23), middle platen

its temperature setting (page 3-47).

 

zone (24), right platen heater (25),

Call your service provider to check

 

right platen zone (26), left platen

wiring, heater, thermistors.

 

haeter (27), left platen zone (28),

 

 

preheat heater (29), postheater #1

 

 

(30), or postheater #2 (31).

 

 

 

 

W-HT-[40 41 42 43] - Heater Bad

Bad thermister reading detected on

The thermister is bad, or the heater

Reading

the middle platen heater (40-42). or

board or I/O board is malfunctioning,

 

middle platen zone (43).

or there is a cable problem.

 

 

 

W-HT-[44 45] - Heater Bad Reading

Bad thermister reading detected on

The thermister is bad, or the heater

 

the right platen heater (44) or zone

board or I/O board is malfunctioning,

 

(45).

or there is a cable problem.

 

 

 

W-HT-[46 47] - Heater Bad Reading

Bad thermister reading detected on

The thermister is bad, or the heater

 

the left platen heater (46) or zone

board or I/O board is malfunctioning,

 

(47).

or there is a cable problem.

 

 

 

W-HT-[48] - Heater Bad Reading

Bad thermister reading detected on

The thermister is bad, or the heater

 

the preheat heater.

board or I/O board is malfunctioning,

 

 

or there is a cable problem.

 

 

 

B-8

Diagnostics

Page 156
Image 156
HP 98SI, 72SI manual Table B-1. Actions and Warnings, Code, Message Cause What to Do