Figure 6-17 Power & Reset Page

NOTE: The BL c-Classtab is available only on HP Integrity server blades. For information on how to set the power management options in Onboard Administrator, see the HP BladeSystem Onboard Administrator User Guide on the HP website at:

http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00705292/c00705292.pdf

Table 6-15lists the fields, buttons, and descriptions.

Table 6-15 Power & Reset Page Description

Fields and Buttons

Description

System Power

The current power state of the system.

System Power Control

A user with power control access can issue the following options for remote control of

 

the system power:

Power Cycle: Turns system power off and on. The delay between off and on is 30 seconds.

Power On: Turns system power on (it has no effect if power is already on).

Power Off: Turns system power off. This is equivalent to forcing the system power off with the front panel power switch. There is no signal sent to the OS to bring the software down before power is turned off. For proper system shutdown, shutdown the OS before issuing this command.

Graceful Shutdown: BMC sends a signal to the OS to shutdown, prior to turning off system power supported by IPF operating systems.

104 Using iLO 2 MP

Page 104
Image 104
HP Integrity iLO 2 MP 5991-6005 manual 15lists the fields, buttons, and descriptions, Power & Reset Page Description