RB [ -nc ] -?

See also: PC, SS

RS: Reset system through the RST signal

Command access level: Power control access

IMPORTANT: During normal system operation, shut down the OS before issuing the RS command.

RS resets the system (except iLO 2 MP) through the RST signal.

Running this command irrecoverably halts all system processing and I/O activity and restarts the system. The effect of this command is similar to cycling the system power. The OS is not notified, no dump is taken as the system shuts down, and so on.

Command line usage and scripting:

RS [ -nc ] -?

See also: TC

SA: Set access LAN/WEB/SSH/IPMI over LAN ports

Command access level: MP configuration access

SA sets access permissions for users logging in to the iLO 2 MP over the LAN. You can set the iLO 2 MP to allow telnet access, web access, SSH, IPMI over LAN, or all four.

If LAN or web users are connected when a disable from this command runs, they are disconnected. Any future incoming connection request to the corresponding port is rejected.

Command line usage and scripting:

SA [ -telnet <ed> ] [ -web <ed> ] [ -ssh <ed> ]

[ -lanipmi <ed> ] [ -command <mpmenusmclp> ] [ -nc ] -?

SNMP: Configure SNMP parameters

Command access level: MP configuration access

SNMP performs the following actions:

Enable or disable the SNMP server. Disabling the SNMP server prevents all access to the SNMP management information base (MIB) objects and also prevents sending of any SNMP alerts.

Enable or disable the SNMP alerts feature separate from the general SNMP server.

NOTE: Currently, the SNMP alert feature is only supported on HP Integrity server blades.

Configure up to four destination IP addresses where SNMP alerts will be sent. Alerts are sent by the iLO 2 MP to these destinations for power shutdown, system reset, and system fatal error events.

Configure the community string, thereby securing the access to the MIB objects.

To configure SNMP parameters, follow these steps:

1.At the MP:CM> prompt, enter SNMP.

2.To change the SNMP status, enter N. Enabled is the default.

3.Enter E to enable or D to disable all SNMP access. The screen displays the new SNMP configuration settings.

4.To change the SNMP alert status, enter T. Disabled is the default.

Text User Interface

77

Page 77
Image 77
HP Integrity iLO 2 MP 5991-6005 RS Reset system through the RST signal, SA Set access LAN/WEB/SSH/IPMI over LAN ports