Table 8-14summarizes these options.

Optional Configuration

Table 8-14summarizes these options.

Table 8-14API reference temperature tables

 

CTL

 

 

 

Density unit and range

 

derivation

 

 

 

 

 

 

 

 

 

 

 

Table

method

Base temperature

Degrees API

Base density

Relative density

 

 

 

 

 

 

 

5A

Method 1

60

°F, non-configurable

0 to +100

 

 

 

 

 

 

 

 

 

5B

Method 1

60

°F, non-configurable

0 to +85

 

 

 

 

 

 

 

 

 

5D

Method 1

60

°F, non-configurable

–10 to +40

 

 

 

 

 

 

 

 

 

23A

Method 1

60

°F, non-configurable

 

 

0.6110 to 1.0760

 

 

 

 

 

 

 

23B

Method 1

60

°F, non-configurable

 

 

0.6535 to 1.0760

 

 

 

 

 

 

 

23D

Method 1

60

°F, non-configurable

 

 

0.8520 to 1.1640

 

 

 

 

 

 

 

53A

Method 1

15

°C, configurable

 

610 to 1075 kg/m3

 

 

 

 

 

 

 

 

53B

Method 1

15

°C, configurable

 

653 to 1075 kg/m3

 

 

 

 

 

 

 

 

53D

Method 1

15

°C, configurable

 

825 to 1164 kg/m3

 

 

 

 

 

 

 

 

 

 

 

 

Reference temperature

Supports

 

 

 

 

 

 

 

6C

Method 2

60

°F, non-configurable

60

°F

Degrees API

 

 

 

 

 

24C

Method 2

60 °F, non-configurable

60 °F

Relative density

 

 

 

 

 

 

 

54C

Method 2

15

°C, configurable

15

°C

Base density in kg/m3

 

 

 

 

 

 

 

8.13.2Configuration procedure

The API configuration parameters are listed and defined in Table 8-15.

Table 8-15API parameters

Variable

Description

 

 

Table type

Specifies the table that will be used for reference temperature and reference density unit. Select

 

the table that matches your requirements. See API reference tables.

 

 

User defined TEC(1)

Thermal expansion coefficient. Enter the value to be used in CTL calculation.

 

 

Temperature units(2)

Read-only. Displays the unit used for reference temperature in the reference table.

 

 

Density units

Read-only. Displays the unit used for reference density in the reference table.

 

 

Reference

Read-only unless Table Type is set to 53x or 54x. If configurable:

temperature

• Specify the reference temperature to be used in CTL calculation.

Enter reference temperature in °C.

(1)Configurable if Table Type is set to 6C, 24C, or 54C.

(2)In most cases, the temperature unit used by the API reference table should also be the temperature unit configured for the transmitter to use in general processing. To configure the temperature unit, see Section 6.3.

To configure the petroleum measurement application:

Using ProLink II, see Figure B-3.

Using a DeviceNet tool, see Table C-10.

Note: This functionality is not available via the display menus.

Using a DeviceNet Tool

Required Configuration

Using the Transmitter

Optional Configuration