Emerson Process Management 2400S manual Table C-10 API Object 0x69 – Instance 1 continued

Models: 2400S

1 188
Download 188 pages 39.36 Kb
Page 171
Image 171
Table C-10API Object (0x69) – Instance 1 continued

Device Profile

Table C-10API Object (0x69) – Instance 1 continued

Attrib

 

 

 

 

 

 

ID

Name

Data type

Service

Mem

Description

Comments

 

 

 

 

 

 

 

7

CTL

REAL

Get

V

Current value

 

 

 

 

 

 

 

 

8

API reference

REAL

Set

NV

The reference

 

 

temperature

 

 

 

temperature to use in the

 

 

 

 

 

 

API calculations

 

 

 

 

 

 

 

 

9

API thermal

REAL

Set

NV

The thermal expansion

 

 

expansion

 

 

 

coefficient to use in the

 

 

coefficient

 

 

 

API calculations

 

 

 

 

 

 

 

 

10

API 2540 CTL

USINT

Set

NV

The table type to use in

• 17 = Table 5A

 

table type

 

 

 

the API calculations

• 18 = Table 5B

 

 

 

 

 

 

• 19 = Table 5D

 

 

 

 

 

 

• 36 = Table 6C

 

 

 

 

 

 

• 49 = Table 23A

 

 

 

 

 

 

• 50 = Table 23B

 

 

 

 

 

 

• 51 = Table 23D

 

 

 

 

 

 

• 68 = Table 24C

 

 

 

 

 

 

• 81 = Table 53A

 

 

 

 

 

 

• 82 = Table 53B

 

 

 

 

 

 

• 83 = Table 53D

 

 

 

 

 

 

• 100 = Table 54C

 

 

 

 

 

 

 

11

Reset API

USINT

Set

V

Resets the API reference

• 1 = Reset

 

reference

 

 

 

volume total

 

 

volume total

 

 

 

 

 

 

 

 

 

 

 

 

12

Reset API

USINT

Set

V

Resets the API reference

• 1 = Reset

 

reference

 

 

 

volume inventory

 

 

volume

 

 

 

 

 

 

inventory

 

 

 

 

 

 

 

 

 

 

 

 

(1)Service code 0x4B.

(2)Service code 0x4C.

C.9

Enhanced Density Object (0x6A)

 

 

 

 

Table C-11Enhanced Density Object (0x6A) – Instance 1

 

 

Attrib

 

 

 

 

 

 

ID

Name

Data type

Service

Mem

Description

Comments

 

 

 

 

 

 

 

1

Density at

REAL

Get

V

Current value

 

 

reference

 

 

 

 

 

 

 

 

 

 

 

 

2

Density (fixed

REAL

Get

V

Current value

 

 

SG units)

 

 

 

 

 

 

 

 

 

 

 

 

3

Standard

REAL

Get

V

Current value

 

 

volume flow rate

 

 

 

 

 

 

 

 

 

 

 

 

4

Standard

REAL

Get

V

Current value

 

 

volume total

 

Reset(1)

 

 

 

 

 

 

 

 

 

 

5

Standard

REAL

Get

V

Current value

 

 

volume

 

Reset(2)

 

 

 

 

inventory

 

 

 

 

 

 

 

 

 

 

 

 

6

Net mass flow

REAL

Get

V

Current value

 

 

rate

 

 

 

 

 

 

 

 

 

 

 

 

7

Net mass flow

REAL

Get

V

Current value

 

 

total

 

Reset(3)

 

 

 

Menus

Device Profile

Display Codes

Index

Configuration and Use Manual

163