Emerson Process Management 2400S manual 2 Summary of input assemblies

Models: 2400S

1 188
Download 188 pages 39.36 Kb
Page 46
Image 46

Using the Transmitter

Table 7-1Process data in DeviceNet objects continued

 

 

Attribute

Data

 

Class

Instance

ID

type

Description

 

 

 

 

 

API Object (0x69)(1)

1

1

REAL

Temperature-corrected density

 

 

 

 

 

 

 

2

REAL

Temperature-corrected (standard) volume flow

 

 

 

 

 

 

 

3

REAL

Temperature-corrected (standard) volume total

 

 

 

 

 

 

 

4

REAL

Temperature-corrected (standard) volume

 

 

 

 

inventory

 

 

 

 

 

 

 

5

REAL

Batch weighted average density

 

 

 

 

 

 

 

6

REAL

Batch weighted average temperature

 

 

 

 

 

 

 

7

REAL

CTL

 

 

 

 

 

Enhanced Density

1

1

REAL

Density at reference temperature

Object (0x6A)(2)

 

 

 

 

 

2

REAL

Density (fixed SG units)

 

 

 

 

 

 

 

 

 

3

REAL

Standard volume flow rate

 

 

 

 

 

 

 

4

REAL

Standard volume flow total

 

 

 

 

 

 

 

5

REAL

Standard volume flow inventory

 

 

 

 

 

 

 

6

REAL

Net mass flow rate

 

 

 

 

 

 

 

7

REAL

Net mass flow total

 

 

 

 

 

 

 

8

REAL

Net mass flow inventory

 

 

 

 

 

 

 

9

REAL

Net volume flow rate

 

 

 

 

 

 

 

10

REAL

Net volume flow total

 

 

 

 

 

 

 

11

REAL

Net volume flow inventory

 

 

 

 

 

 

 

12

REAL

Concentration

 

 

 

 

 

 

 

13

REAL

Density (fixed Baume units)

 

 

 

 

 

(1)Requires petroleum measurement application. See Section 8.13

(2)Requires enhanced density application. See Section 8.14.

Table 7-2Summary of input assemblies

Instance ID

Data description

Size (bytes)

Data type

Description

 

 

 

 

 

1

• Status

5

• BOOL

Mass flow

 

• Mass flow

 

• REAL

 

 

 

 

 

 

2(1)

• Status

5

• BOOL

Volume flow

 

• Volume flow

 

• REAL

 

 

 

 

 

 

3

• Status

9

• BOOL

Mass flow and

 

• Mass flow

 

• REAL

total

 

• Mass total

 

• REAL

 

 

 

 

 

 

4(1)

• Status

9

• BOOL

Volume flow and

 

• Volume flow

 

• REAL

total

 

• Volume total

 

• REAL

 

 

 

 

 

 

5(1)

• Status

21

• BOOL

Basic process

 

• Mass flow

 

• REAL

variables

 

• Temperature

 

• REAL

 

 

• Density

 

• REAL

 

 

• Volume flow

 

• REAL

 

 

• Drive gain

 

• REAL

 

 

 

 

 

 

38

Micro Motion® Model 2400S Transmitters for DeviceNet

Page 46
Image 46
Emerson Process Management 2400S manual 2 Summary of input assemblies