Device Profile

Table C-6Calibration Object (0x65) – Instance 1 continued

Attrib

 

 

 

 

 

 

ID

Name

Data type

Service

Mem

Description

Comments

 

 

 

 

 

 

 

13

D2

REAL

Set

NV

The line-condition density

Unit = g/cm3

 

 

 

 

 

of D2 calibration service

 

 

 

 

 

 

 

 

14

FD

REAL

Set

NV

The line-condition density

Unit = g/cm3

 

 

 

 

 

of FD calibration service

 

 

 

 

 

 

 

 

15

D3

REAL

Set

NV

The line-condition density

Unit = g/cm3

 

 

 

 

 

of D3 calibration service

 

 

 

 

 

 

 

 

16

D4

REAL

Set

NV

The line-condition density

Unit = g/cm3

 

 

 

 

 

of D4 calibration service

 

 

 

 

 

 

 

 

17

Density

REAL

Set

NV

The DT or TC calibration

 

 

temperature

 

 

 

factor

 

 

coefficient

 

 

 

 

 

 

 

 

 

 

 

 

18

FTG

REAL

Set

NV

T-Series: flow TG

 

 

 

 

 

 

coefficient

 

 

 

 

 

 

 

 

19

FFQ

REAL

Set

NV

T-Series: flow FQ

 

 

 

 

 

 

coefficient

 

 

 

 

 

 

 

 

20

DTG

REAL

Set

NV

T-Series: density TG

 

 

 

 

 

 

coefficient

 

 

 

 

 

 

 

 

21

DFQ1

REAL

Set

NV

T-Series: density FQ

 

 

 

 

 

 

coefficient #1

 

 

 

 

 

 

 

 

22

DFQ2

REAL

Set

NV

T-Series: density FQ

 

 

 

 

 

 

coefficient #2

 

 

 

 

 

 

 

 

23

Temperature

REAL

Set

NV

Temperature offset

 

 

offset

 

 

 

 

 

 

 

 

 

 

 

 

24

Temperature

REAL

Set

NV

Temperature slope

 

 

slope

 

 

 

 

 

 

 

 

 

 

 

 

25

Enable

BOOL

Set

NV

Enable or disable

• 0 = Disabled

 

temperature

 

 

 

temperature

• 1 = Enabled

 

comp

 

 

 

compensation

 

 

 

 

 

 

 

 

26

External

REAL

Set

V

The external temperature

 

 

temperature

 

 

 

value from output

 

 

 

 

 

 

assembly instance 51 or

 

 

 

 

 

 

52

 

 

 

 

 

 

 

 

27

Enable pressure

BOOL

Set

NV

Enable or disable

• 0 = Disabled

 

compensation

 

 

 

pressure compensation

• 1 = Enabled

 

 

 

 

 

 

 

28

External

REAL

Set

V

The external pressure

 

 

pressure

 

 

 

value from output

 

 

 

 

 

 

assembly instance 50 or

 

 

 

 

 

 

52

 

 

 

 

 

 

 

 

29

Pressure units

UINT

Set

NV

Units used by external

See Table 6-7for unit

 

 

 

 

 

pressure input

codes.

 

 

 

 

 

 

 

30

Pressure factor

REAL

Set

NV

The pressure correction

 

 

flow

 

 

 

factor for flow

 

 

 

 

 

 

 

 

31

Pressure factor

REAL

Set

NV

The pressure correction

 

 

density

 

 

 

factor for density

 

 

 

 

 

 

 

 

32

Flow cal

REAL

Set

NV

The flow calibration

 

 

pressure

 

 

 

pressure

 

 

 

 

 

 

 

 

148