Default Values and Ranges

Table A-1Transmitter default values and ranges continued

Type

Setting

Default

Range

Comments

 

 

 

 

 

Density

Density damping

1.28 sec

0.0–40.96 sec

User-entered value is

 

 

 

 

corrected to nearest value in

 

 

 

 

list of preset values.

 

 

 

 

 

 

Density units

g/cm3

 

 

 

 

 

 

 

 

Density cutoff

0.2 g/cm3

0.0–0.5 g/cm3

 

 

 

 

 

 

 

D1

0.00000

 

 

 

 

 

 

 

 

D2

1.00000

 

 

 

 

 

 

 

 

K1

1000.00

 

 

 

 

 

 

 

 

K2

50,000.00

 

 

 

 

 

 

 

 

FD

0.00000

 

 

 

 

 

 

 

 

Temp Coefficient

4.44

 

 

 

 

 

 

 

Slug flow

Slug flow low limit

0.0 g/cm3

0.0–10.0 g/cm3

 

 

 

 

 

 

 

Slug flow high limit

5.0 g/cm3

0.0–10.0 g/cm3

 

 

 

 

 

 

 

Slug duration

0.0 sec

0.0–60.0 sec

 

 

 

 

 

 

Temperature

Temperature damping

4.8 sec

0.0–38.4 sec

User-entered value is

 

 

 

 

corrected to nearest lower

 

 

 

 

value in list of preset values.

 

 

 

 

 

 

Temperature units

Deg C

 

 

 

 

 

 

 

 

Temperature calibration factor

1.00000T0.0000

 

 

 

 

 

 

 

Pressure

Pressure units

PSI

 

 

 

 

 

 

 

 

Flow factor

0.00000

 

 

 

 

 

 

 

 

Density factor

0.00000

 

 

 

 

 

 

 

 

Cal pressure

0.00000

 

 

 

 

 

 

 

T-Series sensor

D3

0.00000

 

 

 

 

 

 

 

 

D4

0.00000

 

 

 

 

 

 

 

 

K3

0.00000

 

 

 

 

 

 

 

 

K4

0.00000

 

 

 

 

 

 

 

 

FTG

0.00000

 

 

 

 

 

 

 

 

FFQ

0.00000

 

 

 

 

 

 

 

 

DTG

0.00000

 

 

 

 

 

 

 

 

DFQ1

0.00000

 

 

 

 

 

 

 

 

DFQ2

0.00000

 

 

 

 

 

 

 

Events 1–5

Type

Low

 

 

 

 

 

 

 

 

Variable

Density

 

 

 

 

 

 

 

 

Setpoint

0.0

 

 

 

 

 

 

 

 

Setpoint units

g/cm3

 

 

 

 

 

 

 

132

Micro Motion® Model 2400S Transmitters for DeviceNet

Page 140
Image 140
Emerson Process Management 2400S manual Default Values and Ranges, Type, Setting, Comments