Using the Transmitter

To reset an individual totalizer or inventory:

1.Click ProLink > Totalizer Control or ProLink > ED Totalizer Control (if the enhanced density application is enabled).

2.Click the appropriate button (e.g., Reset Mass Total, Reset Volume Inventory, Reset Net Mass Total).

With a DeviceNet tool

Using a DeviceNet tool, three methods are available for totalizer and inventory control:

EDS – If you have imported the EDS into your DeviceNet tool, you can perform the following functions from the EDS user interface:

-Reset mass totalizer

-Reset mass inventory

-Reset liquid volume totalizer

-Reset liquid volume inventory

-Reset API reference volume total

-Reset API reference volume inventory

-Reset gas standard volume totalizer

-Reset gas standard volume inventory

-Reset ED standard volume total

-Reset ED net mass total

-Reset ED net volume total

-Reset ED standard volume inventory

-Reset ED net mass inventory

-Reset ED net volume inventory

Explicit write – Using a Set, a Reset Total, or a Reset Inventory service, you can perform the functions listed in Table 7-8.

Output assemblies – Five output assemblies are provided, supporting the functions listed in Table 7-9.See the manual entitled Micro Motion Model 2400S Transmitters for DeviceNet: Device Profile for detailed information.

Table 7-8Totalizer and inventory control with a DeviceNet tool using explicit write

To accomplish this

Use this device profile data

 

 

Stop all totalizers and inventories

Analog Input Point Object (0x0A)

 

Instance: 0

 

Attribute ID: 100

 

Service: Set

 

Value: 0

 

 

Start all totalizers and inventories

Analog Input Point Object (0x0A)

 

Instance: 0

 

Attribute ID: 100

 

Service: Set

 

Value: 1

 

 

Reset all totalizers

Analog Input Point Object (0x0A)

 

Instance: 0

 

Attribute ID: 101

 

Service: Set

 

Value: 1

 

 

Using a DeviceNet Tool

Required Configuration

Using the Transmitter

Optional Configuration

Configuration and Use Manual

51

Page 59
Image 59
Emerson Process Management 2400S manual To reset an individual totalizer or inventory