Image 162

Device Profile

Table C-7Diagnostics Object (0x66) – Instance 1 continued

Attrib

 

 

 

 

 

 

 

ID

Name

Data type

Service

Mem

Description

Comments

 

 

 

 

 

 

 

32

9-wire cable

REAL

Get

V

The resistance of the

Unit = ohms

 

RTD resistance

 

 

 

9-wire cable

 

 

 

 

 

 

 

 

 

33

Meter RTD

REAL

Get

V

The resistance of the

Unit = ohms

 

resistance

 

 

 

meter RTD

 

 

 

 

 

 

 

 

 

 

34

Number of

UINT

Get

V

The number of transmitter

 

 

 

power cycles

 

 

 

power cycles

 

 

 

 

 

 

 

 

 

35

Power on time

Unsigned 32

Get

V

The cumlative amount of

Seconds since last

 

 

 

Reset(1)

 

time the tranmitter has

reset

 

 

 

 

 

 

been on since the last

 

 

 

 

 

 

 

reset (Class 0x01,

 

 

 

 

 

 

 

Attribute 0x05)

 

 

 

 

 

 

 

 

 

36

Line RTD

REAL

Get

V

The resistance of the

Unit = ohms

 

 

 

 

 

process line RTD

 

 

 

 

 

 

 

 

 

37

Actual target

REAL

Get

V

The amplitude the

Unit = mV/HZ

 

amplitude

 

 

 

transmitter is attempting

 

 

 

 

 

 

 

to drive the sensor

 

 

 

 

 

 

 

 

 

38

Input voltage

REAL

Get

V

The number of volts on

Unit = volts

 

 

 

 

 

the power input terminals

 

 

 

 

 

 

 

 

 

39

Drive current

REAL

Get

V

The drive current

Unit = milliamps

 

 

 

 

 

 

 

 

40

Alarm 7

UINT

Get

V

A collection of status bits

• 0x0001

= K1/FCF

 

 

 

 

 

 

Combination

 

 

 

 

 

 

Unrecognized

 

 

 

 

 

 

• 0x0002

= Warming

 

 

 

 

 

 

Up

 

 

 

 

 

 

 

• 0x0004

= Low Power

 

 

 

 

 

 

• 0x0008

= Tube not

 

 

 

 

 

 

Full

 

 

 

 

 

 

 

• 0x0010

= Meter Ver

 

 

 

 

 

 

Fault

 

 

 

 

 

 

 

• 0x0020

= Meter Ver

 

 

 

 

 

 

Info

 

 

 

 

 

 

 

• 0x0040

=UI PROM

 

 

 

 

 

 

error

 

 

 

 

 

 

 

• 0x0080

= Not Used

 

 

 

 

 

 

• 0x0100

= Not Used

 

 

 

 

 

 

0x0200

= Not Used

 

 

 

 

 

 

• 0x0400

= Not Used

 

 

 

 

 

 

• 0x0800

= Not Used

 

 

 

 

 

 

• 0x1000

= Not Used

 

 

 

 

 

 

• 0x2000

= Not Used

 

 

 

 

 

 

• 0x4000

= Not Used

 

 

 

 

 

 

• 0x8000

= Not Used

 

 

 

 

 

 

 

 

154

Micro Motion® Model 2400S Transmitters for DeviceNet

Page 162
Image 162