Emerson Process Management 2400S manual

Models: 2400S

1 188
Download 188 pages 39.36 Kb
Page 167
Image 167
Manual background

Device Profile

Table C-7Diagnostics Object (0x66) – Instance 1 continued

Attrib

 

 

 

 

 

 

ID

Name

Data type

Service

Mem

Description

Comments

 

 

 

 

 

 

 

83

Factory flow

REAL

Get

NV

The flow signal offset at

Unit = microseconds

 

signal offset at

 

 

 

zero flow when calibrated

 

 

zero flow

 

 

 

at the factory

 

 

 

 

 

 

 

 

84

Discrete event

USINT

Set

V

The action that will be

• 1 = Start sensor zero

 

action code

 

 

 

performed by the event

• 2 = Reset mass total

 

 

 

 

 

specified in Attribute 85

• 3 = Reset volume

 

 

 

 

 

 

total

 

 

 

 

 

 

• 4 = Reset API volume

 

 

 

 

 

 

total

 

 

 

 

 

 

• 5 = Reset ED volume

 

 

 

 

 

 

total

 

 

 

 

 

 

• 6 = Reset ED net

 

 

 

 

 

 

mass total

 

 

 

 

 

 

• 7 = Reset ED net

 

 

 

 

 

 

volume total

 

 

 

 

 

 

• 8 = Reset all totals

 

 

 

 

 

 

• 9 = Start/stop all

 

 

 

 

 

 

totals

 

 

 

 

 

 

• 18 = Increment ED

 

 

 

 

 

 

curve

 

 

 

 

 

 

• 21 = Reset GSV total

 

 

 

 

 

 

 

85

Discrete event

USINT

Set

NV

The discrete event that is

• 57 = Discrete event 1

 

assignment

 

 

 

assigned to the action

• 58 = Discrete event 2

 

 

 

 

 

referenced in Attribute 84

• 59 = Discrete event 3

 

 

 

 

 

 

• 60 = Discrete event 4

 

 

 

 

 

 

• 61 = Discrete event 5

 

 

 

 

 

 

• 251 = None

 

 

 

 

 

 

(1) Service code 0x4D.

 

 

 

 

 

C.6

Sensor Information Object (0x67)

 

 

 

 

Table C-8Sensor Information Object (0x67) – Instance 1

 

 

Attrib

 

 

 

 

 

 

ID

Name

Data type

Service

Mem

Description

Comments

 

 

 

 

 

 

 

1

Sensor serial

UDINT

Set

NV

The serial number of the

 

 

number

 

 

 

sensor

 

 

 

 

 

 

 

 

2

Sensor type

SHORT

Get

NV

A string that represents

For example, F200,

 

 

STRING

 

 

the type of sensor

CMF025

 

 

 

 

 

 

 

3

Sensor type

USINT

Set

NV

The type of sensor

• 0 = Curved tube

 

code

 

 

 

 

• 1 = Straight tube

 

 

 

 

 

 

 

Menus

Device Profile

Display Codes

Index

Configuration and Use Manual

159

Page 167
Image 167
Emerson Process Management 2400S manual