Emerson Process Management 2400S manual Local Display Object

Models: 2400S

1 188
Download 188 pages 39.36 Kb
Page 168
Image 168
Local Display Object (0x68)

Device Profile

Table C-8Sensor Information Object (0x67) – Instance 1 continued

Attrib

 

 

 

 

 

 

ID

Name

Data type

Service

Mem

Description

Comments

 

 

 

 

 

 

 

4

Sensor material

USINT

Set

NV

The material of the

• 0 = None

 

 

 

 

 

sensor’s case

• 3 = Hastelloy C-22

 

 

 

 

 

 

• 4 = Monel

 

 

 

 

 

 

• 5 = Tantalum

 

 

 

 

 

 

• 6 = Titanium

 

 

 

 

 

 

• 19 = 316L stainless

 

 

 

 

 

 

steel

 

 

 

 

 

 

• 23 = Inconel

 

 

 

 

 

 

• 252 = Unknown

 

 

 

 

 

 

• 253 = Special

 

 

 

 

 

 

 

5

Liner material

USINT

Set

NV

The material of the

• 0 = None

 

 

 

 

 

sensor’s liner

• 10 = PTFE (Teflon)

 

 

 

 

 

 

• 11 = Halar

 

 

 

 

 

 

• 16 = Tefzel

 

 

 

 

 

 

• 251 = None

 

 

 

 

 

 

• 252 = Unknown

 

 

 

 

 

 

• 253 = Special

 

 

 

 

 

 

 

6

Flange type

USINT

Set

NV

The type of process

• 0 = ANSI 150

 

 

 

 

 

connection on the sensor

• 1 = ANSI 300

 

 

 

 

 

 

• 2 = ANSI 600

 

 

 

 

 

 

• 5 = PN 40

 

 

 

 

 

 

• 7 = JIS 10K

 

 

 

 

 

 

• 8 = JIS 20K

 

 

 

 

 

 

• 9 = ANSI 900

 

 

 

 

 

 

• 10 = Sanitary clamp

 

 

 

 

 

 

fitting

 

 

 

 

 

 

• 11 = Union

 

 

 

 

 

 

• 12 = PN 100

 

 

 

 

 

 

• 252 = Unknown

 

 

 

 

 

 

• 253 = Special

 

 

 

 

 

 

 

C.7

Local Display Object (0x68)

 

 

 

 

Table C-9Local Display Object (0x68) – Instance 1

 

 

 

Attrib

 

 

 

 

 

 

ID

Name

Data type

Service

Mem

Description

Comments

 

 

 

 

 

 

 

1

Scroll rate

USINT

Set

NV

The rate at which each

Unit = seconds

 

 

 

 

 

variable will be displayed

 

 

 

 

 

 

 

 

2

Backlight control

BOOL

Set

NV

Whether the backlight is

• 0 = Off

 

 

 

 

 

on or off

• 1 = On

 

 

 

 

 

 

 

3

Backlight

USINT

Set

NV

The brightness of the

0 (off) to 63 (full on)

 

intensity

 

 

 

backlight

 

4

Display variable USINT

Set

V

Displays the variable

 

1

 

 

associated with the code

 

 

 

 

on the local display

See Table C-15for codes. All codes are valid except for 251 (None).

160

Micro Motion® Model 2400S Transmitters for DeviceNet

Page 168
Image 168
Emerson Process Management 2400S manual Local Display Object