Device Profile
Table
Attrib |
|
|
|
|
|
|
ID | Name | Data type | Service | Mem | Description | Comments |
|
|
|
|
|
|
|
12 | Alarm status 1 | UINT | Get | V | A collection of status bits | • 0x0001 = NV error |
|
|
|
|
|
| (CP) |
|
|
|
|
|
| • 0x0002 = RAM error |
|
|
|
|
|
| (CP) |
|
|
|
|
|
| • 0x0004 = RTI failure |
|
|
|
|
|
| • 0x0008 = Sensor |
|
|
|
|
|
| failure |
|
|
|
|
|
| • 0x0010 = |
|
|
|
|
|
| Temperature out of |
|
|
|
|
|
| range |
|
|
|
|
|
| • 0x0020 = Calibration |
|
|
|
|
|
| failed |
|
|
|
|
|
| • 0x0040 = Other |
|
|
|
|
|
| failure |
|
|
|
|
|
| • 0x0080 = Transmitter |
|
|
|
|
|
| initializing |
|
|
|
|
|
| • 0x0100 = Not used |
|
|
|
|
|
| • 0x0200 = Not used |
|
|
|
|
|
| • 0x0400 = Simulation |
|
|
|
|
|
| mode On |
|
|
|
|
|
| • 0x0800 = Not used |
|
|
|
|
|
| • 0x1000 = Watchdog |
|
|
|
|
|
| error |
|
|
|
|
|
| • 0x2000 = Not used |
|
|
|
|
|
| • 0x4000 = Not used |
|
|
|
|
|
| • 0x8000 = Fault |
|
|
|
|
|
|
|
13 | Alarm status 2 | UINT | Get | V | A collection of status bits | • 0x0001 = Not used |
|
|
|
|
|
| • 0x0002 = Not used |
|
|
|
|
|
| • 0x0004 = Not used |
|
|
|
|
|
| • 0x0008 = Not used |
|
|
|
|
|
| • 0x0010 = Density out |
|
|
|
|
|
| of range |
|
|
|
|
|
| • 0x0020 = Drive out of |
|
|
|
|
|
| range |
|
|
|
|
|
| • 0x0040 = CEM |
|
|
|
|
|
| communications error |
|
|
|
|
|
| • 0x0080 = Not used |
|
|
|
|
|
| • 0x0100 = |
|
|
|
|
|
| memory error (CP) |
|
|
|
|
|
| • 0x0200 = RAM error |
|
|
|
|
|
| (CP) |
|
|
|
|
|
| • 0x0400 = Sensor |
|
|
|
|
|
| failure |
|
|
|
|
|
| • 0x0800 = |
|
|
|
|
|
| Temperature out of |
|
|
|
|
|
| range |
|
|
|
|
|
| • 0x1000 = Input out of |
|
|
|
|
|
| range |
|
|
|
|
|
| • 0x2000 = Not used |
|
|
|
|
|
| • 0x4000 = Transmitter |
|
|
|
|
|
| not characterized |
|
|
|
|
|
| • 0x8000 = RTI failure |
|
|
|
|
|
|
|
150 | Micro Motion® Model 2400S Transmitters for DeviceNet™ |