Device Profile

Table C-9Local Display Object (0x68) – Instance 1 continued

Attrib

 

 

 

 

 

 

ID

Name

Data type

Service

Mem

Description

Comments

 

 

 

 

 

 

 

26

Enable offline

BOOL

Set

NV

Enable or disable the

• 0 = Disabled

 

password

 

 

 

password requirement to

• 1 = Enabled

 

 

 

 

 

access the offline menu

 

 

 

 

 

 

 

 

27

Offline password

UINT

Set

NV

The offline password for

0–9999

 

 

 

 

 

entering the offline menu

 

 

 

 

 

 

 

 

28

Update period

UINT

Set

NV

The period in which the

Unit = milliseconds

 

 

 

 

 

display is updated

 

 

 

 

 

 

 

 

29

Process variable

USINT

Set

V

The process variable in

See Table C-15for

 

index

 

 

 

which the precision will be

codes.

 

 

 

 

 

set in Attribute 30

 

 

 

 

 

 

 

 

30

Process variable

USINT

Set

NV

The number of digits

0–5

 

precision

 

 

 

displayed to the right of

 

 

 

 

 

 

the decimal point for the

 

 

 

 

 

 

process variable selected

 

 

 

 

 

 

with Attribute 29

 

 

 

 

 

 

 

 

31

Language

USINT

Set

NV

Display language

• 0 = English

 

 

 

 

 

selection

• 1 = German

 

 

 

 

 

 

• 2 = French

 

 

 

 

 

 

• 3 = Katakana(1)

 

 

 

 

 

 

• 4 = Spanish

 

 

 

 

 

 

 

32

Enable IrDA port

USINT

Set

NV

Enable or disable the

• 0 = Disabled

 

 

 

 

 

IrDA port

• 1 = Enabled

 

 

 

 

 

 

(1) Not available in this release.

 

 

 

 

 

C.8

API Object (0x69)

 

 

 

 

 

Table C-10API Object (0x69) – Instance 1

 

 

 

Attrib

 

 

 

 

 

 

ID

Name

Data type

Service

Mem

Description

Comments

 

 

 

 

 

 

 

1

Temperature

REAL

Get

V

Current value

 

 

corrected

 

 

 

 

 

 

density

 

 

 

 

 

 

 

 

 

 

 

 

2

Temperature

REAL

Get

V

Current value

 

 

corrected

 

 

 

 

 

 

(standard)

 

 

 

 

 

 

volume flow

 

 

 

 

 

 

 

 

 

 

 

 

3

Temperature

REAL

Get

V

Current value

 

 

corrected

 

Reset(1)

 

 

 

 

(standard)

 

 

 

 

 

 

volume total

 

 

 

 

 

 

 

 

 

 

 

 

4

Temperature

REAL

Get

V

Current value

 

 

corrected

 

Reset(2)

 

 

 

 

(standard)

 

 

 

 

 

 

volume

 

 

 

 

 

 

inventory

 

 

 

 

 

 

 

 

 

 

 

 

5

Batch weighted

REAL

Get

V

Current value

 

 

average density

 

 

 

 

 

 

 

 

 

 

 

 

6

Batch weighted

REAL

Get

V

Current value

 

 

average

 

 

 

 

 

 

temperature

 

 

 

 

 

 

 

 

 

 

 

 

162

Micro Motion® Model 2400S Transmitters for DeviceNet

Page 170
Image 170
Emerson Process Management 2400S manual Table C-10API Object 0x69 Instance