Using the Transmitter

Table 7-2Summary of input assemblies continued

Instance ID

Data description

Size (bytes)

Data type

Description

 

 

 

 

 

16(1)(3)

• Status

21

• BOOL

Petroleum

 

• API temperature-corrected density

 

• REAL

measurement

 

• API temperature-corrected volume flow

 

• REAL

application

 

• API temperature-corrected volume inventory

 

• REAL

 

 

• API average temperature-corrected density

 

• REAL

 

 

• API average temperature

 

• REAL

 

 

 

 

 

 

17(1)(4)

• Status

21

• BOOL

Enhanced

 

• Mass flow

 

• REAL

density

 

• Volume flow

 

• REAL

application

 

• Temperature

 

• REAL

 

 

• Enhanced density reference density

 

• REAL

 

 

• Enhanced density specific gravity

 

• REAL

 

 

 

 

 

 

18(1)(4)

• Status

21

• BOOL

Enhanced

 

• Mass flow

 

• REAL

density

 

• Volume flow

 

• REAL

application

 

• Temperature

 

• REAL

 

 

• Density

 

• REAL

 

 

• Enhanced density concentration

 

• REAL

 

 

 

 

 

 

19(1)(4)

• Status

21

• BOOL

Enhanced

 

• Mass flow

 

• REAL

density

 

• Volume flow

 

• REAL

application

 

• Temperature

 

• REAL

 

 

• Density

 

• REAL

 

 

• Enhanced density Baume

 

• REAL

 

 

 

 

 

 

20(4)

• Status

21

• BOOL

Enhanced

 

• Temperature

 

• REAL

density

 

• Density

 

• REAL

application

 

• Enhanced density net mass flow

 

• REAL

 

 

• Enhanced density net mass total

 

• REAL

 

 

• Enhanced density net mass inventory

 

• REAL

 

 

 

 

 

 

21(4)

• Status

21

• BOOL

Enhanced

 

• Temperature

 

• REAL

density

 

• Density

 

• REAL

application

 

• Enhanced density net volume flow

 

• REAL

 

 

• Enhanced density net volume total

 

• REAL

 

 

• Enhanced density net volume inventory

 

• REAL

 

 

 

 

 

 

22(4)

• Status

21

• BOOL

Enhanced

 

• Mass Flow

 

• REAL

density

 

• Temperature

 

• REAL

application

 

• Density

 

• REAL

 

 

• Enhanced density reference density

 

• REAL

 

 

• Enhanced density net mass flow

 

• REAL

 

 

 

 

 

 

23(1)(4)

• Status

21

• BOOL

Enhanced

 

• Volume flow

 

• REAL

density

 

• Temperature

 

• REAL

application

 

• Density

 

• REAL

 

 

• Enhanced density reference density

 

• REAL

 

 

• Enhanced density net volume flow

 

• REAL

 

 

 

 

 

 

40

Micro Motion® Model 2400S Transmitters for DeviceNet

Page 48
Image 48
Emerson Process Management 2400S manual API average temperature-corrected density