Emerson Process Management 2400S manual 6.3.4Temperature units, 6 Temperature measurement units

Models: 2400S

1 188
Download 188 pages 39.36 Kb
Page 41
Image 41
6.3.4Temperature units

Required Transmitter Configuration

6.3.4Temperature units

The default temperature measurement unit is °C. See Table 6-6for a complete list of temperature measurement units.

Table 6-6Temperature measurement units

 

 

Temperature unit

 

 

 

 

 

 

 

Display

ProLink II

DeviceNet tool

DeviceNet code

Unit description

 

 

 

 

 

°C

°C

degC

0x1200

Degrees Celsius

 

 

 

 

 

°F

°F

degF

0x1201

Degrees Fahrenheit

 

 

 

 

 

°R

°R

degR

0x1202

Degrees Rankine

 

 

 

 

 

°K

°K

Kelvin

0x1203

Kelvin

 

 

 

 

 

6.3.5Pressure units

The flowmeter does not measure pressure. You need to configure the pressure units if either of the following is true:

You will configure pressure compensation (see Section 9.2). In this case, configure the pressure unit to match the pressure unit used by the external pressure device.

You will use the Gas Wizard, you will enter a reference pressure value, and you need to change the pressure unit to match the reference pressure value (see Section 8.2).

If you do not know whether or not you will use pressure compensation or the Gas Wizard, you do not need to configure a pressure unit at this time. You can always configure the pressure unit later.

The default pressure measurement unit is PSI. See Table 6-7for a complete list of pressure measurement units.

Table 6-7Pressure measurement units

 

Pressure unit

 

 

 

 

 

 

 

Display

ProLink II

DeviceNet tool

DeviceNet code

Unit description

 

 

 

 

 

FTH2O

Ft Water @ 68°F

FtH2O(68F)

0x082D

Feet water @ 68 °F

 

 

 

 

 

INW4C

In Water @ 4°C

InH2O(4C)

0x0858

Inches water @ 4 °C

 

 

 

 

 

INW60

In Water @ 60°F

InH2O(60F)

0x0859

Inches water @ 60 °F

 

 

 

 

 

INH2O

In Water @ 68°F

InH2O(68F)

0x082C

Inches water @ 68 °F

 

 

 

 

 

mmW4C

mm Water @ 4°C

mmH2O(4C)

0x085A

Millimeters water @ 4 °C

 

 

 

 

 

mmH2O

mm Water @ 68°F

mmH2O(68F)

0x082E

Millimeters water @ 68 °F

 

 

 

 

 

mmHG

mm Mercury @ 0°C

mmHg(0C)

0x1303

Millimeters mercury @ 0 °C

 

 

 

 

 

INHG

In Mercury @ 0°C

InHg(0C)

0x1304

Inches mercury @ 0 °C

 

 

 

 

 

PSI

PSI

psi

0x1300

Pounds per square inch

 

 

 

 

 

BAR

bar

bar

0x1307

Bar

 

 

 

 

 

mBAR

millibar

mbar

0x1308

Millibar

 

 

 

 

 

G/SCM

g/cm2

g/cm2

0x082F

Grams per square centimeter

 

 

 

 

 

KG/SCM

kg/cm2

kg/cm2

0x0830

Kilograms per square centimeter

 

 

 

 

 

PA

pascals

PA

0x1309

Pascals

 

 

 

 

 

KPA

Kilopascals

kPA

0x130A

Kilopascals

 

 

 

 

 

Using a DeviceNet Tool

Required Configuration

Using the Transmitter

Optional Configuration

Configuration and Use Manual

33