Table 10-1 Numeric Codes and Text Messages (continued)
Control panel message | Description | Recommended action | |
|
|
|
|
Provisioning file contained on the USB key | 1. | Recreate the provisioning file using third | |
header identifier | has been corrupted or is not a valid version |
| party management console software. |
| for the current ME firmware. | 2. | If the error persists and system BIOS |
|
| ||
|
|
| has been recently updated, restore |
|
|
| previous system BIOS version. |
|
|
| Otherwise, update the ME firmware |
|
|
| version. |
|
| 3. | If the error still persists, replace the |
|
|
| system board. |
|
|
|
|
Provisioning file contained on the USB key is | 1. | Reboot the computer. | |
mismatch version | not a valid version for the current ME | 2. | If the error persists and system BIOS |
| firmware. | ||
|
| has been recently updated, restore | |
|
|
| |
|
|
| previous system BIOS version. |
|
|
| Otherwise, update the ME firmware |
|
|
| version. |
|
| 3. | If the error still persists, replace the |
|
|
| system board. |
|
|
|
|
Error occurred during MEBx execution which | 1. | Reboot the computer. | |
| fails into the “General” grouping. Status | 2. | If the error persists, update to the latest |
| information displayed along with the error | ||
|
| BIOS version and ME firmware version. | |
| provides further clarity into the failure. MEBx |
| |
|
|
| |
| handles transference of information between | 3. | If the error still persists, replace the |
| the system BIOS and ME firmware. | ||
|
| system board. | |
|
|
| |
|
|
|
|
Error occurred during MEBx execution which | 1. | Reboot the computer. | |
| fails into “ME” grouping. | 2. | If the error persists, update to the latest |
|
| ||
|
|
| BIOS version and ME firmware version. |
|
| 3. | If the error still persists, replace the |
|
|
| system board. |
|
|
|
|
Error occurred during MEBx execution which | 1. | Reboot the computer. | |
| fails into “AMT” grouping. | 2. | If the error persists, update to the latest |
|
| ||
|
|
| BIOS version and ME firmware version. |
|
| 3. | If the error still persists, replace the |
|
|
| system board. |
|
|
|
|
Error occurred during MEBx execution which | 1. | Reboot the computer. | |
| fails into “MEI or HECI” grouping. | 2. | If the error persists, update to the latest |
|
| ||
|
|
| BIOS version and ME firmware version. |
|
| 3. | If the error still persists, replace the |
|
|
| system board. |
|
|
|
|
Special system configurations with reduced | 1. | Reboot the computer. | |
| ME firmware image require BIOS control of | 2. | If the error persists, update to the latest |
| ME firmware upgrading. A failure has | ||
|
| BIOS version and ME firmware version. | |
| occurred after the ME firmware update |
| |
|
|
| |
| process in which the BIOS could not relock | 3. | If the error still persists, replace the |
| the ME firmware region. | ||
|
| system board. | |
|
|
| |
|
|
|
|