HX200/HX200L-2000/HX300/HX300L/HX400

(2)Emergency stop of external system

External emergency stop device (button etc.) can be connected to the safety electric circuit in accordance with applied standard for the emergency stop circuit.

Emergency stop connection of the external system

SEQUENCE BOARD(BD461)

 

Emergency Stop Channel 1 LED

 

 

 

 

OPERATIONAL PANEL

 

 

 

 

 

 

 

 

 

 

 

 

Emergency Stop Switch

 

 

EMST1A

CNOP:17

CNOP

 

EM_STOP1

P1(24V)

 

 

EMST1A

 

 

 

EMST1B

CNOP:18

 

EMST1B

 

 

 

EMST2A

CNOP:19

 

EMST2A

 

Emergency Stop Channel 2 LED

EMST2B

CNOP:20

 

EMST2B

 

 

 

 

 

 

 

 

 

 

 

 

TEACHING PENDANT

M1(0V)

 

 

 

 

CNRTP

Emergency Stop Switch

 

 

 

 

 

 

 

 

 

 

EM_STOP2

 

 

 

 

CNTPS

 

 

 

EMST1B

A1

K

 

 

 

 

 

 

 

EMST1C

B1

 

L

 

 

 

EMST2B

A2

 

M

 

 

 

EMST2C

B2

 

N

 

 

 

 

 

 

EXTERNAL SYSTEM

 

 

 

 

 

Emergency Stop Switch

 

 

EMST1C

JP1

EMST1C

 

 

 

TBEXT:1

 

 

 

 

M1(0V)

TBEXT:2

 

M1

 

 

 

EMST2C

TBEXT:3

 

EMST2C

 

 

 

P1(24V)

TBEXT:4

 

P1

 

 

 

 

JP2

 

 

 

 

ESOUT1

TBEXT:5

 

 

 

 

 

ESOUT2

TBEXT:6

 

 

 

ES2

ES1

 

 

 

 

 

 

RUN CHAIN

 

 

 

 

 

Fig 1.7 Emergency Stop Connection of External System

When using the emergency stop of the external system, connect the Terminal No. 1 (ES1) & No. 2 (M1,0V Common) or No. 3 (ES2) & No. 4 (P1,24V Common) of the terminal block of BD461 to the external emergency stop line, and you must open JP1 or JP2.

At this time, the emergency stop must be connected to be Normal On and it must be check for proper operation during test run.

1-28