5. Maintenance

Grease Replacement

Make the H-Axis Arm vertical for ground.(H:90°-Floor Type, H:0°-Shelf Type )

Remove the grease outlet plug.

Inject the grease into the grease inlet using a grease gun.

￿Grease type : Molywhite RE00

￿Amount of grease : 1,600cc

The grease replacement is complete when new grease appears in the outlet port. The new grease can be distinguished from the old one by color.

Move the H-Axis for a few minutes to eject the old grease and then add grease until the new grease appears in the outlet port.

Wipe the outlet port with a cloth and attach the plug with seal tape.

5-5