HX200/HX200L-2000/HX300/HX300L/HX400

2.6. Details of Wrist Axis Attachment Surface

When attaching the operating tool to the mechanical interface of robot's wrist flange, fasten it with a bolt at P.C.D. 125.

Fig 2.9 Details of Wrist Axis Attachment Surface : [HX300/400/300L]

Ø10H7 D.P.16

12

 

 

6-M10 TAP

 

 

D.P.13(PCD 125)

 

Ø180

Ø76H7

 

6-M10 TAP

 

2-Ø10H7 D.P.16

D.P.14(PCD 160)

Fig 2.10 Details of Wrist Axis Attachment Surface : [HX200L]

2-12