IBM System Storage DR550

Version 3.0 ------

17 March 2006

Page 10

provide high performance and functionality. Events such as upgrades to support the latest version of DS4000 Storage Manager can also often be executed without stopping operations.

IBM DS4100 Storage Server in the DR550 at a glance

Characteristics

 

Model

1724-100

RAID controller

Dual active 2 GB RAID controllers

Cache

512 MB total, battery-backed

Host interface

4 - Fibre Channel (FC) Switched and FC Arbitrated Loop (FC-

 

AL) standard

Drive interface

Redundant 2 Gbps FC-AL connections

EXP100 drives

400 GB 7200 RPM SATA disk drives

EXP100 enclosures

14 400 GB SATA disk drive modules, offering up to 5.6

 

Terabytes (TB) of physical capacity per enclosure

RAID

Level 5 configured. RAID-10 can be configured at the

 

customer’s site using an optional IBM Services consultant

Maximum drives supported

112 Serial ATA drives (using 8 EXP100 Expansion Units) per

 

DS4100

Fans

Dual redundant, hot-swappable

Management software

IBM DS4000 Storage Manager version 9.12.65 (Special

 

version for exclusive use with DR550)

IBM TotalStorage SAN Switch

Two IBM TotalStorage SAN Fibre Channel Switches are used to interconnect both P5 520 servers with the DS4100s to create a SAN (dual node configurations). Tape attachment such as the 3592, TS1120 or LTO can be done using the additional ports on the switches. The switches (2005-B16) build two independent SANs, which are designed to be fully redundant for high availability. This implementation in the DR550 is designed to provide high performance, scalability, and high fault tolerance.

For the single node configurations, only one switch (2005-B16) included. This creates a single independent SAN and can be used for both disk and tape access.

The 2005-B16 is a 16-port, dual speed, auto-sensing fibre channel switch. Eight ports are populated with 2 gigabit shortwave transceivers when the DR550 is configured for single copy mode. Twelve ports are populated with 2 gigabit short wave tranceivers when the DR550 is configured for enhanced remote volume mirroring. This dual implementation is designed to provide a fault tolerant fabric topology, to help avoid single points of failure.

IBM SAN Fibre Channel Switch 2005-B16

Each switch in the DR550 comes pre-zoned by ports. Both switches are configured with distinct zones as illustrated below:

Accessing the Switch(es)

If you need to access the switch(es) to review the zoning information, error messages, or other information, you will need to connect Ethernet cables (provided by the customer) to the Ethernet port

IBM Storage Systems

Copyright © 2006 by International Business Machines Corporation

 

 

Page 10
Image 10
IBM DR550 manual Characteristics, Accessing the Switches