IBM System Storage DR550

Version 3.0 ------

17 March 2006

Page 78

 

 

 

 

Ethernet Connection (for management purposes

2 (only 1 if single node) SAN connections using Fiber-optic cables and extension (DWDM or CWDM technology)

Recovery from the primary failure

To recover from a failure at the primary site, you will need to do the following steps at the secondary DR550.

For Single Node implementation (Assuming the AIX server within the secondary DR550 is operational):

Remember that the remote server is not configured to bring up the SSAM server automatically at boot time. If it does start automatically, then disable auto start of the SSAM server using the following commands (execute ‘‘rmitab autoserv’’ command at AIX prompt as root id.) and disable varyon volume groups. (execute ‘‘chvg --a’n’ <volume groupname> - for all volume groups except rootvg). --this is still true for operational AIX just like one below….not to have

TSM up and VGs are down.

1.From the integrated consoles, logon to AIX using the DR550 userid

2.Switch to Root and enter the appropriate password

3.From Root, execute ‘‘cfgmgr’’

4.Enter the following commands

o varyonvg --y TSMApps, hdisk2 o varyonvg --y TSMDbLogs, hdisk3 o varyonvg --y TSMDbBkup, hdisk4 o varyonvg --y TSMStg hdisk5

5.Then issue the following mount commands o mount /tsm,

o mount /tsmDb, o mount /tsmLog,

o mount /tsmdbbkup

6.Change directories using the following command: cd /usr/tivoli/tsm/server/bin

7.Issue the following command: nohup rc.adsmserv &

IBM Storage Systems

Copyright © 2006 by International Business Machines Corporation

 

 

Page 78
Image 78
IBM DR550 manual Recovery from the primary failure, Ethernet Connection for management purposes