Page 112

Height: 43.7 mm (1.72 in)

Weight: 12.9 kg (44.8.4 lb) Operating Environment

Temperature:

10-35 degrees C (50-95 degrees F) at 0-914 m (0-3000 ft)

10-32 degrees C (50-90 degrees F) at 914-2,133 m (3,000 – 7,000 ft) Relative humidity: 8% to 80%

Electrical Power (per power supply) Voltage Range

100 – 127 (nominal) V ac: 50Hz or 60 Hz, 5.6 A 200 - 240 (nominal) V ac; 50 Hz or 60 Hz, 1.7A

Power Source loading: 0.55 kVA

Maximum altitude: 2,135m (7,000 ft)

Noise Level (normal operation): 4.4 bels

Heat dissipation: 1878 BTU per hour

7316-TF3

Physical Specifications Width: 485 mm (19 in)

Depth: 635 mm to 730 mm (29.0 in to 44.8.74 in)

Height (closed): 43.0 mm (1.7 in)

Height (opened): 410 mm (16.1 in)

Weight: 12.8 kg (44.8.2 lbs) LCD Panel

Size: 432 mm (17 in) diagonal, 337.92 (H) x 270.34 mm (V) (13.3 in x 10.6 in)

Type: a-Si TFT active matrix

Pixel pitch: 0.264 mm (H) x 0.264 mm (V) Operating Environment

Not applicable

7014-T00 Rack

Physical Specifications

Width: 644 mm (25.4 in) with side panels

Depth: 1098 mm (43.3 in) with front and read doors

Height: 1804 mm (71.0 in with standard AC power

Weight (empty): 244 kg (535 lbs) Operating Environment

Temperature:

10-40 degrees C Relative humidity: 8% to 80% Maximum wet bulb: 27 degrees C Electrical Power (per power supply)

Voltage Range – 200 to 240 V ac 50/60 Hz Operating Current: 1.65-3.9 Amperes Power: 390 Watts

Frequency: 50/60 Hz

Power source loading: 4.8 kVA per PDU (rack may have up to 4 PDUs)

Noise Level (normal operation): 0.0 bels