b. If you have just made changes to or have just turned on the system unit, you
might need to wait up to 30 seconds before detailed information about the
SSA network becomes available to the service aids.
4. When you have solved a problem, press F3 (Esc and 3 on some consoles) to
leave the display; then press Enter to reselect it. The display shows the new
status of the SSA links.
Configuration Verification Service Aid
The Configuration Verification service aid enables you to determine the relationship
between SSA logical units (hdisks) and SSA physical disk drives (pdisks). It also
displays the connection information and operational status of the disk drives.
Note: User applications communicate with the hdisks; error data is logged against
the pdisks.
To use the Configuration Verification service aid:
1. Select Configuration Verification from the SSA Service Aids menu to display a list
of pdisks and hdisks (see “Starting the SSA Service Aids” on page 7-31).
┌──────────────────────────────────────────────────────────────────────────────────┐
│ SSA SERVICE AIDS 8ð238ð │
┌──────────────────────────────────────────────────────────────────────────────────┐
│ CONFIGURATION VERIFICATION 8ð239ð │
│ Move cursor onto selection, then press Enter.
{TOP}
pdiskð 22222222 ðð-ð3-P 9.1 GB SSA F Physical Disk Drive
pdisk1 33333333 ðð-ð5-P 9.1 GB SSA F Physical Disk Drive
pdisk2 44444444 ðð-ð7-P 9.1 GB SSA F Physical Disk Drive
hdisk3 22222222 ðð-ð3-L SSA Logical Disk Drive
hdisk4 33333333 ðð-ð5-L SSA Logical Disk Drive
hdisk5 44444444 ðð-ð7-L SSA Logical Disk Drive
{BOTTOM}
│ F3=Cancel F1ð=Exit
└──────────────────────────────────────────────────────────────────────────────────┘
Chapter 7. Using the Service Aids 7-41